Literature DB >> 9559609

Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model.

I M Cheifetz1, D M Craig, G Quick, J J McGovern, M L Cannon, R M Ungerleider, P K Smith, J N Meliones.   

Abstract

OBJECTIVES: In a pediatric swine model, the effects of increasing tidal volumes and the subsequent development of pulmonary overdistention on cardiopulmonary interactions were studied. The objective was to test the hypothesis that increasing tidal volumes adversely affect pulmonary vascular mechanics and cardiac output. An additional goal was to determine whether the effects of pulmonary overdistention are dependent on delivered tidal volume and/or positive end-expiratory pressure (PEEP, end-expiratory lung volume).
DESIGN: Prospective, randomized, controlled laboratory trial.
SETTING: University research laboratory.
SUBJECTS: Eleven 4- to 6-wk-old swine, weighing 8 to 12 kg.
INTERVENTIONS: Piglets with normal lungs were anesthetized, intubated, and paralyzed. After median sternotomy, pressure transducers were placed in the right ventricle, pulmonary artery, and left atrium. An ultrasonic flow probe was placed around the pulmonary artery.
MEASUREMENTS AND MAIN RESULTS: The swine were ventilated and data were collected with delivered tidal volumes of 10, 15, 20, and 25 mL/kg and PEEP settings of 5 and 10 cm H2O in a random order. Pulmonary overdistention was defined as a decrease in dynamic compliance of > or =20% when compared with a compliance measured at a baseline tidal volume of 10 mL/kg. At this baseline tidal volume, airway pressure-volume curves did not demonstrate pulmonary overdistention. Tidal volumes and airway pressures were measured by a pneumotachometer and the Pediatric Pulmonary Function Workstation. Inspiratory time (0.75 sec), FIO2 (0.3), and minute ventilation were held constant. We evaluated the pulmonary vascular and cardiac effects of the various tidal volume and PEEP settings by measuring pulmonary vascular resistance, pulmonary characteristic impedance, and cardiac output. When compared with a tidal volume of 10 mL/kg, a tidal volume of 20 mL/kg resulted in a significant decrease in dynamic compliance from 10.5 +/- 0.9 to 8.4 +/- 0.6 mL/cm H2O (p = .02) at a constant PEEP of 5 cm H2O. The decrease in dynamic compliance of 20% indicated the presence of pulmonary overdistention by definition. As the tidal volume was increased from 10 to 20 mL/kg, pulmonary vascular resistance (1351 +/- 94 vs. 2266 +/- 233 dyne x sec/cm5; p = .004) and characteristic impedance (167 +/- 12 vs. 219 +/- 22 dyne x sec/cm5; p = .02) significantly increased, while cardiac output significantly decreased (951 +/- 61 vs. 708 +/- 48 mL/min; p = .001). Each of these effects of pulmonary overdistention were further magnified when the tidal volume was increased to 25 mL/kg. The tidal volume-induced alterations in pulmonary vascular mechanics, characteristic impedance, and cardiac output occurred to a greater degree when the PEEP was increased to 10 cm H2O. Pulmonary vascular resistance and characteristic impedance were significantly increased and cardiac output significantly decreased for all tidal volumes studied at a PEEP of 10 cm H2O as compared with 5 cm H2O.
CONCLUSIONS: Increasing tidal volumes, increasing PEEP levels, and the development of pulmonary overdistention had detrimental effects on the cardiovascular system by increasing pulmonary vascular resistance and characteristic impedance while significantly decreasing cardiac output. Delivered tidal volumes of >15 mL/kg should be utilized cautiously. Careful monitoring of respiratory mechanics and cardiac function, especially in neonatal and pediatric patients, is warranted.

Entities:  

Mesh:

Year:  1998        PMID: 9559609     DOI: 10.1097/00003246-199804000-00020

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  15 in total

1.  Mean airway pressure and response to inhaled nitric oxide in neonatal and pediatric patients.

Authors:  George M Hoffman; Leif D Nelin
Journal:  Lung       Date:  2005 Nov-Dec       Impact factor: 2.584

2.  Impact of implementing 5 potentially better respiratory practices on neonatal outcomes and costs.

Authors:  Bernadette M Levesque; Leslie A Kalish; Justine LaPierre; Maureen Welch; Virginia Porter
Journal:  Pediatrics       Date:  2011-06-13       Impact factor: 7.124

3.  Prevalence and Outcomes of Pediatric In-Hospital Cardiac Arrest Associated With Pulmonary Hypertension.

Authors:  Ryan W Morgan; Alexis A Topjian; Yan Wang; Natalie J Atkin; Todd J Kilbaugh; Francis X McGowan; Robert A Berg; Laura Mercer-Rosa; Robert M Sutton; Adam S Himebauch
Journal:  Pediatr Crit Care Med       Date:  2020-04       Impact factor: 3.624

4.  Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report.

Authors:  N Nelson; B Janerot-Sjöberg
Journal:  Crit Care       Date:  2001-01-05       Impact factor: 9.097

5.  [Preserved spontaneous breathing during partial liquid ventilation. Results of experimental animal studies and their clinical implications].

Authors:  H D Hummler; F Pohlandt; A Schulze
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

6.  Cardiac index and oxygen delivery during low and high tidal volume ventilation strategies in patients with acute respiratory distress syndrome: a crossover randomized clinical trial.

Authors:  Giuseppe Natalini; Cosetta Minelli; Antonio Rosano; Pierluigi Ferretti; Carmine R Militano; Carlo De Feo; Achille Bernardini
Journal:  Crit Care       Date:  2013-07-23       Impact factor: 9.097

7.  Elevated positive end-expiratory pressure decreases cardiac index in a rhesus monkey model.

Authors:  Patrick A Ross; Robinder G Khemani; Sarah S Rubin; Anoopindar K Bhalla; Christopher J L Newth
Journal:  Front Pediatr       Date:  2014-12-03       Impact factor: 3.418

8.  Comparison of different inspiratory triggering settings in automated ventilators during cardiopulmonary resuscitation in a porcine model.

Authors:  Dingyu Tan; Jun Xu; Shihuan Shao; Yangyang Fu; Feng Sun; Yazhi Zhang; Yingying Hu; Joseph Walline; Huadong Zhu; Xuezhong Yu
Journal:  PLoS One       Date:  2017-02-10       Impact factor: 3.240

9.  Efficacy of Manual Ventilation Techniques During Cardiopulmonary Resuscitation in Dogs.

Authors:  Kate Hopper; Marlis L Rezende; Angela Borchers; Steven E Epstein
Journal:  Front Vet Sci       Date:  2018-10-01

10.  Low tidal volume ventilation ameliorates left ventricular dysfunction in mechanically ventilated rats following LPS-induced lung injury.

Authors:  Thomas G V Cherpanath; Lonneke Smeding; Alexander Hirsch; Wim K Lagrand; Marcus J Schultz; A B Johan Groeneveld
Journal:  BMC Anesthesiol       Date:  2015-10-07       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.