Literature DB >> 11175217

Characteristics of SonoVuetrade mark.

Michel Schneider.   

Abstract

The advances made by ultrasonography in the last decade, in parallel with the development of ultrasound contrast agents, have opened a wide range of potential breakthroughs in the field of ultrasound imaging. SonoVue(trade mark) is a new echocontrast agent made of microbubbles stabilized by phospholipids and containing sulphur hexafluoride (SF6), an innocuous gas. The suspension of the microbubbles is stable over the time following reconstitution. The bubble concentration of SonoVue(trade mark) is between 100 and 500 million per ml. The mean bubble diameter is 2.5 µm and more than 90% of the bubbles are smaller than 8 µm. Following intravenous injection, the bubble suspension is submitted to pressure increases. SF(6), a high molecular weight gas with low solubility in water, was selected since laboratory tests showed that it confers to the bubbles a good resistance to pressure changes as those that occur in the left ventricle, in the pulmonary capillaries, or in the coronary circulation. The high bubble concentration, combined with a favorable size distribution profile, provides SonoVue(trade mark) with a strong echogenicity. SonoVue(trade mark) shows a peak in the backscatter coefficient at about 3 MHz. With regard to the gas contained in the bubbles, its pharmacokinetics have been assessed during a study in human volunteers. Following intravenous administration of 0.3 ml/kg of SonoVue(trade mark) (i.e., approximately ten times the imaging dose), the blood level curve showed a distribution half-life of about 1 minute and an elimination half-life of about 6 minutes. More than 80% of the administered gas is exhaled via the lungs after 11 minutes. Extensive studies in animals and humans have confirmed the outstanding safety profile of this second generation contrast agent and its capability in providing a clinically useful ultrasound signal enhancement for the evaluation of cardiac function and extracardiac vessel abnormalities. Thanks to the long persistence of SF(6) microbubbles, SonoVue(trade mark) is also potentially useful in the assessment of myocardial perfusion, as well as microcirculatory disorders.

Entities:  

Year:  1999        PMID: 11175217     DOI: 10.1111/j.1540-8175.1999.tb00144.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  51 in total

1.  Vascular and perfusion imaging using encapsulated laser-polarized helium.

Authors:  V Callot; E Canet; J Brochot; Y Berthezène; M Viallon; H Humblot; A Briguet; H Tournier; Y Crémillieux
Journal:  MAGMA       Date:  2001-03       Impact factor: 2.310

Review 2.  [Ultrasound contrast agents: substance classes, pharmacokinetics, clinical applications, safety aspects].

Authors:  C Krestan
Journal:  Radiologe       Date:  2005-06       Impact factor: 0.635

3.  Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

Authors:  Marianne Gauthier; Ingrid Leguerney; Jessie Thalmensi; Mohamed Chebil; Sarah Parisot; Pierre Peronneau; Alain Roche; Nathalie Lassau
Journal:  World J Radiol       Date:  2011-03-28

4.  The influence of distance between microbubbles on the fluid flow produced during ultrasound exposure.

Authors:  Carolyn E Schutt; Stuart D Ibsen; William Thrift; Sadik C Esener
Journal:  J Acoust Soc Am       Date:  2014-12       Impact factor: 1.840

Review 5.  Evolving clinical applications of contrast-enhanced ultrasound (CEUS) in the abdominal aorta.

Authors:  Vasileios Rafailidis; Sasan Partovi; Alexander Dikkes; Dean A Nakamoto; Nami Azar; Daniel Staub
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

6.  Impact of the arterial input function on microvascularization parameter measurements using dynamic contrast-enhanced ultrasonography.

Authors:  Marianne Gauthier; Stéphanie Pitre-Champagnat; Farid Tabarout; Ingrid Leguerney; Mélanie Polrot; Nathalie Lassau
Journal:  World J Radiol       Date:  2012-07-28

7.  Effect of microbubble size on fundamental mode high frequency ultrasound imaging in mice.

Authors:  Shashank Sirsi; Jameel Feshitan; James Kwan; Shunichi Homma; Mark Borden
Journal:  Ultrasound Med Biol       Date:  2010-05-05       Impact factor: 2.998

8.  Evaluation of in vivo antitumor effects of ANT2 shRNA delivered using PEI and ultrasound with microbubbles.

Authors:  D H Park; B K Jung; Y S Lee; J Y Jang; M K Kim; J K Lee; H Park; J Seo; C W Kim
Journal:  Gene Ther       Date:  2015-01-15       Impact factor: 5.250

9.  Contrast-enhanced ultrasound-guided musculoskeletal biopsies: our experience and technique.

Authors:  Steven P Daniels; Lori Mankowski Gettle; Donna G Blankenbaker; Kenneth S Lee; Andrew B Ross
Journal:  Skeletal Radiol       Date:  2020-09-15       Impact factor: 2.199

10.  Activation of microbubbles by low-level therapeutic ultrasound enhances the antitumor effects of doxorubicin.

Authors:  Shuang Yang; Pan Wang; Xiaobing Wang; Xiaomin Su; Quanhong Liu
Journal:  Eur Radiol       Date:  2014-08-06       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.