Literature DB >> 11174994

Albunex Does Not Increase the Sensitivity of the Lung to Pulsed Ultrasound.

C. H. Raeman1, D. Dalecki, S. Z. Child, R. S. Meltzer, E. L. Carstensen.   

Abstract

If cavitation in the vasculature of the lung is the physical mechanism responsible for lung hemorrhage, then addition of cavitation nuclei to the blood should enhance the bioeffect. To test the cavitation hypothesis, the extent of lung hemorrhage in mice injected with the echocontrast agent, Albunex(R), was compared to lung hemorrhage in animals injected with saline. Animals were exposed for 5 minutes to 1.1-MHz pulsed ultrasound (10 µs pulse length, 100-Hz pulse repetition frequency) at a peak positive pressure at the surface of the animal of 2 MPa. This exposure is approximately twice the threshold pressure amplitude for lung hemorrhage. Lesion areas did not differ significantly in the two groups of animals and were approximately equal to the lesion area in uninjected mice from an earlier study where acoustic exposures were the same. Neither this study nor a related study of hemolysis in vivo suggests that use of Albunex in echocardiographic procedures increases the risk of bioeffects.

Entities:  

Year:  1997        PMID: 11174994     DOI: 10.1111/j.1540-8175.1997.tb00764.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  14 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Safety of ultrasound contrast agents.

Authors:  Jarl A Jakobsen; Raymond Oyen; Henrik S Thomsen; Sameh K Morcos
Journal:  Eur Radiol       Date:  2005-01-21       Impact factor: 5.315

6.  Pulmonary Capillary Hemorrhage Induced by Fixed-Beam Pulsed Ultrasound.

Authors:  Douglas L Miller; Chunyan Dou; Krishnan Raghavendran
Journal:  Ultrasound Med Biol       Date:  2015-04-29       Impact factor: 2.998

7.  Acoustic Fountains and Atomization at Liquid Surfaces Excited by Diagnostic Ultrasound.

Authors:  Brandon Patterson; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2019-05-14       Impact factor: 2.998

8.  Frequency dependence of kidney injury induced by contrast-aided diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  Ultrasound Med Biol       Date:  2008-05-15       Impact factor: 2.998

9.  Safety and bio-effects of ultrasound contrast agents.

Authors:  Gail ter Haar
Journal:  Med Biol Eng Comput       Date:  2009-07-14       Impact factor: 2.602

Review 10.  [Ultrasound contrast agents. Pharmaceutical drug safety and bioeffects].

Authors:  M Krix; J W Jenne
Journal:  Radiologe       Date:  2007-09       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.