Infrared patient positioning for stereotactic radiosurgery of extracranial tumors.

L T Wang1, T D Solberg, P M Medin, R Boone.   

Abstract

We report on a novel, non-invasive patient positioning system for radiosurgery of extracranial tumors. The system consisted of infrared cameras and reflective markers attached to the skin. Because localization accuracy is critical in radiosurgery, we performed a theoretical analysis of the accuracy of the system. A computer simulation program modeled errors in marker position, and was used to predict errors in targeting and study methods for minimizing errors. The use of redundant markers improved the overall accuracy of targeting. Experimental data was collected using a rigid torso phantom and correlated with theoretical results. The accuracy of the infrared system was compared with existing systems.

Entities:  

Mesh:

Year:  2001        PMID: 11165218     DOI: 10.1016/s0010-4825(00)00026-3

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  9 in total

Review 1.  Radiotherapy for renal cell carcinoma: renaissance of an overlooked approach.

Authors:  Shankar Siva; Gargi Kothari; Alexander Muacevic; Alexander V Louie; Ben J Slotman; Bin S Teh; Simon S Lo
Journal:  Nat Rev Urol       Date:  2017-06-20       Impact factor: 14.432

2.  Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

Authors:  Jacek Dmochowski; Kenneth R Hoffmann; Vikas Singh; Jinhui Xu; Daryl P Nazareth
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  The impact of leaf width and plan complexity on DMLC tracking of prostate intensity modulated arc therapy.

Authors:  Tobias Pommer; Marianne Falk; Per Rugaard Poulsen; Paul J Keall; Ricky T O'Brien; Per Munck af Rosenschöld
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

4.  Feasibility of differential geometry-based features in detection of anatomical feature points on patient surfaces in range image-guided radiation therapy.

Authors:  Mazen Soufi; Hidetaka Arimura; Katsumasa Nakamura; Fauzia P Lestari; Freddy Haryanto; Taka-Aki Hirose; Yoshiyuki Umedu; Yoshiyuki Shioyama; Fukai Toyofuku
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-13       Impact factor: 2.924

Review 5.  Spinal radiosurgery: technology and clinical outcomes.

Authors:  M Avanzo; P Romanelli
Journal:  Neurosurg Rev       Date:  2008-09-24       Impact factor: 3.042

6.  Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy.

Authors:  Erminia Infusino; Lucio Trodella; Sara Ramella; Rolando M D'Angelillo; Carlo Greco; Aurelia Iurato; Luca E Trodella; Alessandro Nacca; Patrizia Cornacchione; Alessandra Mameli
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  Clinical assessment and characterization of a dual tube kilovoltage X-ray localization system in the radiotherapy treatment room.

Authors:  Sung-Woo Lee; Jian-Yue Jin; Huaiqun Guan; Flavious Martin; Jae Ho Kim; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2008-01-13       Impact factor: 2.102

8.  Performance and characteristics of an IR localizing system for radiation therapy.

Authors:  Yulia Lyatskaya; Hsiao-Ming Lu; Lee Chin
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

9.  Impact of patient positioning uncertainty in noncoplanar intracranial stereotactic radiotherapy.

Authors:  Yoshihiro Tanaka; Masataka Oita; Shinichiro Inomata; Toshiaki Fuse; Yuichi Akino; Kohei Shimomura
Journal:  J Appl Clin Med Phys       Date:  2020-01-20       Impact factor: 2.102

  9 in total