Literature DB >> 11158118

Controlled comparison of BacT/ALERT FAN aerobic medium and BATEC fungal blood culture medium for detection of fungemia.

L C McDonald1, M P Weinstein, J Fune, S Mirrett, L G Reimer, L B Reller.   

Abstract

Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both FAN and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11158118      PMCID: PMC87787          DOI: 10.1128/JCM.39.2.622-624.2001

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

2.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

Review 3.  Laboratory detection of fungemia.

Authors:  D J Geha; G D Roberts
Journal:  Clin Lab Med       Date:  1994-03       Impact factor: 1.935

4.  Nosocomial bloodstream infection in critically ill patients. Excess length of stay, extra costs, and attributable mortality.

Authors:  D Pittet; D Tarara; R P Wenzel
Journal:  JAMA       Date:  1994-05-25       Impact factor: 56.272

5.  Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children.

Authors:  C A Petti; A K Zaidi; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

Review 6.  Candidemia in a tertiary care hospital: epidemiology, risk factors, and predictors of mortality.

Authors:  V J Fraser; M Jones; J Dunkel; S Storfer; G Medoff; W C Dunagan
Journal:  Clin Infect Dis       Date:  1992-09       Impact factor: 9.079

7.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb

8.  Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.

Authors:  M L Wilson; T E Davis; S Mirrett; J Reynolds; D Fuller; S D Allen; K K Flint; F Koontz; L B Reller
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

9.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

10.  Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube.

Authors:  N K Henry; C A McLimans; A J Wright; R L Thompson; W R Wilson; J A Washington
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

View more
  4 in total

1.  Biographical feature: Melvin P. Weinstein, M.D.

Authors:  Betty A Forbes
Journal:  J Clin Microbiol       Date:  2013-06-05       Impact factor: 5.948

2.  Comparison of media for optimal recovery of Candida albicans and Candida glabrata from blood culture.

Authors:  J E Moore; R McMullan
Journal:  Ir J Med Sci       Date:  2003 Apr-Jun       Impact factor: 1.568

3.  Comparison of Mycosis IC/F and plus Aerobic/F media for diagnosis of fungemia by the bactec 9240 system.

Authors:  Marie-Hélène Meyer; Valérie Letscher-Bru; Benoît Jaulhac; Jocelyn Waller; Ermanno Candolfi
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

4.  Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for candida growth detection.

Authors:  Lynn L Horvath; Benjamin J George; Clinton K Murray; Linda S Harrison; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

  4 in total