Literature DB >> 11154372

The fate of the poly-L-lactic acid interference screw after anterior cruciate ligament reconstruction.

V Martinek1, R Seil, C Lattermann, S C Watkins, F H Fu.   

Abstract

We report the persistence of a poly-L-lactic acid (PLLA) interference screw 2.5 years after anterior cruciate ligament (ACL) reconstruction with Achilles tendon allograft. The arthroscopy was performed because the patient sustained a reinjury of the ACL graft, making ACL revision surgery necessary. At the time of arthroscopy, both PLLA screws were macroscopically still intact but could not be removed in 1 piece. No inflammation could be observed either macroscopically or in the histologic analysis. The biopsy specimen from the femoral insertion of the graft showed parts of the PLLA material surrounded by scar tissue. This case shows that biodegradation of PLLA material in the knee joint causes no irritation and can take several years, even if the material is in contact with the synovial fluid.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11154372     DOI: 10.1053/jars.2001.7797

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  10 in total

1.  Recurrent locking of knee joint caused by intraarticular migration of bioabsorbable tibial interference screw after arthroscopic ACL reconstruction.

Authors:  Andreas Appelt; Martin Baier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-28       Impact factor: 4.342

2.  Comparison of bioabsorbable interference screws and posts for distal fixation in anterior cruciate ligament reconstruction.

Authors:  Krzysztof Gaweda; Jacek Walawski; Robert Wegłowski; Wojciech Krzyzanowski
Journal:  Int Orthop       Date:  2007-12-07       Impact factor: 3.075

3.  Meta-analysis comparing bioabsorbable versus metal interference screw for adverse and clinical outcomes in anterior cruciate ligament reconstruction.

Authors:  Pat Laupattarakasem; Malinee Laopaiboon; Weerachai Kosuwon; Wiroon Laupattarakasem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

4.  Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL) Reconstruction using a Semitendinosus-gracilis Graft: A Case Report.

Authors:  Me Deborah Huang; Hc Andrew Tan
Journal:  Malays Orthop J       Date:  2012-11

5.  Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction.

Authors:  Casper Foldager; Bent W Jakobsen; Bent Lund; Svend Erik Christiansen; Lotte Kashi; Lone R Mikkelsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-16       Impact factor: 4.342

6.  Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report.

Authors:  Michael T Hirschmann; Tom Adler; Helmut Rasch; Rolf W Hügli; Niklaus F Friederich; Markus P Arnold
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2010-09-16

7.  Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction.

Authors:  M Ettinger; T Werner-Lebeda; T Calliess; M Omar; C Becher; M Ezechieli; M Klintschar; M Petri
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-27       Impact factor: 4.342

8.  Severe cartilage damage by broken poly-L-lactic acid (PLLA) interference screw after ACL reconstruction.

Authors:  Burkhard Lembeck; Nikolaus Wülker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-11-11       Impact factor: 4.342

9.  Paradoxical tunnel enlargement after ACL reconstruction with hamstring autografts when using β-TCP containing interference screws for tibial aperture fixation- prospectively comparative study.

Authors:  Joon Ho Wang; Eun Su Lee; Byung Hoon Lee
Journal:  BMC Musculoskelet Disord       Date:  2017-09-16       Impact factor: 2.362

10.  Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction.

Authors:  M Ettinger; R Karkosch; H Horstmann; P Savov; T Calliess; T Smith; M Petri
Journal:  J Exp Orthop       Date:  2018-09-29
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.