Literature DB >> 26818555

Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction.

M Ettinger1, T Werner-Lebeda1, T Calliess1, M Omar2, C Becher1, M Ezechieli1, M Klintschar3, M Petri4.   

Abstract

PURPOSE: This cadaveric study compares the biomechanical properties of femoral graft fixation in ACL reconstruction of either quadriceps or hamstring tendon grafts with four different interference screws. The hypothesis was that quadriceps tendon grafts provide at least equal results concerning gap formation during cyclic loading and ultimate failure load compared to hamstring tendon grafts with four different interference screws.
METHODS: Eighty porcine femora underwent interference screw fixation of human tendon grafts for ACL reconstruction. Either quadriceps (Q) or hamstring (H) tendon grafts and four different bioabsorbable interference (Wolf (W), Storz (S), Mitek (M), Arthrex (A)) screws were used, resulting in 8 groups with 10 specimens per groups (WQ, WH, SQ, SH, MQ, MH, AQ, AH). Biomechanical analysis included pretensioning the constructs with 60 N for 30 s, then cyclic loading of 500 cycles between 60 and 250 N at 1 Hz in a servohydraulic testing machine, with measurement of elongation and stiffness including video measurements. After this, ultimate failure load and failure mode analysis were performed.
RESULTS: No statistically significant difference could be noted between the groups regarding gap formation during cyclic loading [Cycles 21-500 (mm): WQ 3.6 ± 0.8, WH 3.9 ± 1.4, SQ 3.6 ± 0.8, SH 3.3 ± 1.5, MQ 4.3 ± 0.8, MH 4.6 ± 1.0, AQ 4.8 ± 0.8, AH 4.3 ± 1.5, n.s.], stiffness during cyclic loading [Cycles 21-500 (N/mm): WQ 72.9 ± 16.9, WH 71.6 ± 20.7, SQ 69.5 ± 23.9, SH 77.4 ± 25.1, MQ 59.6 ± 11.2, MH 48.4 ± 15.4, AQ 48.8 ± 12.7, AH 51.9 ± 22.2, n.s.], and ultimate failure load [(N): WQ 474.4 ± 88.0, WH 579.3 ± 124.2, SQ 493.9 ± 105.2, SH 576.0 ± 90.4, MQ 478.6 ± 59.0, MH 543.9 ± 119.7, AQ 480.2 ± 93.8, AH 497.8 ± 74.2, n.s.].
CONCLUSIONS: Quadriceps tendon grafts yield comparable biomechanical results for femoral interference screw fixation in ACL reconstruction compared to hamstring tendon grafts. From a clinical perspective, quadriceps tendon grafts should therefore be considered as a good option in ACL reconstruction in the future.

Entities:  

Keywords:  Anterior cruciate ligament; Anterior cruciate ligament reconstruction; Biomechanics; Femoral fixation; Hamstring tendon graft; Interference screw; Quadriceps tendon graft

Mesh:

Year:  2016        PMID: 26818555     DOI: 10.1007/s00167-016-4001-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  50 in total

Review 1.  Biodegradable implants in sports medicine: the biological base.

Authors:  A Weiler; R F Hoffmann; A C Stähelin; H J Helling; N P Südkamp
Journal:  Arthroscopy       Date:  2000-04       Impact factor: 4.772

2.  Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation.

Authors:  D G Nagarkatti; B P McKeon; B S Donahue; J P Fulkerson
Journal:  Am J Sports Med       Date:  2001 Jan-Feb       Impact factor: 6.202

3.  Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament.

Authors:  J Höher; S U Scheffler; J D Withrow; G A Livesay; R E Debski; F H Fu; S L Woo
Journal:  J Orthop Res       Date:  2000-05       Impact factor: 3.494

4.  A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation.

Authors:  J-U Buelow; R Siebold; A Ellermann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-02-27       Impact factor: 4.342

5.  Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

Authors:  Andreas Weiler; Reinhard F G Hoffmann; Hermann J Bail; Oliver Rehm; Norbert P Südkamp
Journal:  Arthroscopy       Date:  2002-02       Impact factor: 4.772

6.  Development of a perforated biodegradable interference screw.

Authors:  Patrick Hunt; Frank N Unterhauser; Michael J Strobel; Andreas Weiler
Journal:  Arthroscopy       Date:  2005-03       Impact factor: 4.772

7.  Biomechanical evaluation of different anterior cruciate ligament fixation techniques for hamstring graft.

Authors:  E Monaco; L Labianca; A Speranza; A M Agrò; G Camillieri; C D'Arrigo; A Ferretti
Journal:  J Orthop Sci       Date:  2010-02-12       Impact factor: 1.601

8.  Quadriceps tendon and patellar ligament: cryosectional anatomy and structural properties in young adults.

Authors:  H U Stäubli; L Schatzmann; P Brunner; L Rincón; L P Nolte
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1996       Impact factor: 4.342

9.  Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw.

Authors:  Eric Steenlage; Jeff C Brand; Darren L Johnson; David N M Caborn
Journal:  Arthroscopy       Date:  2002-10       Impact factor: 4.772

10.  Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.

Authors:  S A Rodeo; S P Arnoczky; P A Torzilli; C Hidaka; R F Warren
Journal:  J Bone Joint Surg Am       Date:  1993-12       Impact factor: 5.284

View more
  5 in total

1.  Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading.

Authors:  J Glasbrenner; C Domnick; M J Raschke; T Willinghöfer; C Kittl; P Michel; D Wähnert; Mirco Herbort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-27       Impact factor: 4.342

2.  Interference screw insertion angle has no effect on graft fixation strength for insertional Achilles tendon reconstruction.

Authors:  Ziying Wu; Hongyun Li; Shiyi Chen; Kui Ma; Shengkun Li; Peng Zhang; Yinghui Hua
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-14       Impact factor: 4.342

Review 3.  Quadricep ACL Reconstruction Techniques and Outcomes: an Updated Scoping Review of the Quadricep Tendon.

Authors:  Dan Cohen; David Slawaska-Eng; Mahmoud Almasri; Andrew Sheean; Darren de Sa
Journal:  Curr Rev Musculoskelet Med       Date:  2021-11-10

4.  Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction.

Authors:  M Ettinger; R Karkosch; H Horstmann; P Savov; T Calliess; T Smith; M Petri
Journal:  J Exp Orthop       Date:  2018-09-29

5.  Quadriceps and hamstring tendon autografts in ACL reconstruction yield comparably good results in a prospective, randomized controlled trial.

Authors:  Hauke Horstmann; Maximilian Petri; Uwe Tegtbur; Gernot Felmet; Christian Krettek; Michael Jagodzinski
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-19       Impact factor: 3.067

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.