Literature DB >> 11152780

MR hydrometry to assess exocrine function of the pancreas: initial results of noninvasive quantification of secretion.

J T Heverhagen1, D Müller, A Battmann, N Ishaque, D Boehm, M Katschinski, H J Wagner, K J Klose.   

Abstract

PURPOSE: To evaluate magnetic resonance (MR) hydrometry, a method of quantifying fluid amounts by using MR imaging, for assessing the exocrine function of the pancreas after stimulation with secretin.
MATERIALS AND METHODS: Images were obtained with a single-shot turbo spin-echo sequence by using a 1.0-T magnet with a quadrature body coil. Image postprocessing and evaluation were performed at an external workstation by using a specially designed histogram algorithm that translates the MR signal intensity of duodenal filling into an actual amount of duodenal fluid. This algorithm was tested in vitro and in vivo. Finally, MR hydrometry results in five patients were correlated with those of the secretin-cerulein test.
RESULTS: The phantom measurements showed a high correlation (r = 0.99) between the actual amount of fluid in the imaging volume and the calculated results. In vivo, the ability of MR hydrometry to enable exact quantification of fluid amounts was demonstrated. In correlating the signal intensity of duodenal filling with the exact amount of additional fluid in the duodenum in volunteers, a coefficient of 0.043 gray tones per pixel per milliliter was calculated. The correlation (r) between secretin-stimulated duodenal fluid output estimated by using tube aspiration and that estimated by using MR hydrometry was 0.946 (P <.05).
CONCLUSION: MR hydrometry is a promising noninvasive method of assessing fluid output as a measure of exocrine pancreatic function.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11152780     DOI: 10.1148/radiology.218.1.r01ja2061

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  10 in total

Review 1.  Functional MRCP in pancreatic and periampullary disease.

Authors:  C Matos; C Winant; M Delhaye; J Devière
Journal:  Int J Gastrointest Cancer       Date:  2001

Review 2.  Non-invasive investigation of gastrointestinal functions with magnetic resonance imaging: towards an "ideal" investigation of gastrointestinal function.

Authors:  W Schwizer; M Fox; A Steingötter
Journal:  Gut       Date:  2003-06       Impact factor: 23.059

3.  Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation.

Authors:  N J Hilliard; R Hawkes; A J Patterson; M J Graves; A N Priest; S Hunter; C Lees; P A Set; D J Lomas
Journal:  Eur Radiol       Date:  2016-01-20       Impact factor: 5.315

4.  Quantification of pancreatic exocrine function with secretin-enhanced magnetic resonance cholangiopancreatography: normal values and short-term effects of pancreatic duct drainage procedures in chronic pancreatitis. Initial results.

Authors:  M A Bali; A Sztantics; T Metens; M Arvanitakis; M Delhaye; J Devière; C Matos
Journal:  Eur Radiol       Date:  2005-07-01       Impact factor: 5.315

5.  Anatomic variants of the pancreatic duct and their clinical relevance: an MR-guided study in the general population.

Authors:  Robin Bülow; Peter Simon; Robert Thiel; Patrick Thamm; Philip Messner; Markus M Lerch; Julia Mayerle; Henry Völzke; Norbert Hosten; Jens-Peter Kühn
Journal:  Eur Radiol       Date:  2014-08-15       Impact factor: 5.315

6.  Diagnostic Performance of Contrast-Enhanced MRI With Secretin-Stimulated MRCP for Non-Calcific Chronic Pancreatitis: A Comparison With Histopathology.

Authors:  Guru Trikudanathan; Sidney P Walker; Satish Munigala; Ben Spilseth; Ahmad Malli; Yusheng Han; Melena Bellin; Srinath Chinnakotla; Ty Dunn; Timothy L Pruett; Gregory J Beilman; Jose Vega Peralta; Mustafa A Arain; Stuart K Amateau; Sarah J Schwarzenberg; Shawn Mallery; Rajeev Attam; Martin L Freeman
Journal:  Am J Gastroenterol       Date:  2015-09-15       Impact factor: 10.864

Review 7.  Quantitative pancreatic MRI: a pathology-based review.

Authors:  Manil D Chouhan; Louisa Firmin; Samantha Read; Zahir Amin; Stuart A Taylor
Journal:  Br J Radiol       Date:  2019-06-14       Impact factor: 3.039

8.  MRI of slow flow in artificial duct in swine.

Authors:  Johan Castberg Hellund; Knut Jørgen Labori; Bjørn Atle Bjørnbeth; Kjell Inge Gjesdal; Jonn Terje Geitung
Journal:  Eur Radiol       Date:  2004-02-07       Impact factor: 5.315

9.  Quantitative secretin MRCP (MRCPQ): results in 215 patients with known or suspected pancreatic pathology.

Authors:  A R Gillams; W R Lees
Journal:  Eur Radiol       Date:  2007-07-10       Impact factor: 5.315

10.  Quantification of pancreatic exocrine function of chronic pancreatitis with secretin-enhanced MRCP.

Authors:  Yun Bian; Li Wang; Chao Chen; Jian-Ping Lu; Jia-Bao Fan; Shi-Yue Chen; Bing-Hui Zhao
Journal:  World J Gastroenterol       Date:  2013-11-07       Impact factor: 5.742

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.