New Clarion electrode with positioner: insertion studies.

T Lenarz1, J Kuzma, B P Weber, G Reuter, J Neuburger, R D Battmer, J E Goldring.   

Abstract

A new straight thin electrode array (universal electrode) was designed to be used together with a positioner, which will place the electrode array at the medial wall (modiolus) of the cochlea. The study objectives were to demonstrate safety and ease of insertion, tissue trauma, electrode position, and depth for universal and standard electrodes in human temporal bones; to test functional properties in cats; and to determine the surgical procedure and electrophysiological benefits in a clinical study. The cadaver study demonstrated the ease of insertion for the universal electrode and the positioner without tissue damage. An average gain of insertion depth of 180 degrees was achieved with the positioner. Animal studies demonstrated a reduction in threshold of 6 dB for the electrical auditory brain stem response (EABR). Neither additional cochlear damage nor additional connective tissue formation was found. The intraoperative human study findings showed a marked reduction of threshold for both EABR and stapedius reflex thresholds. Impedances were increased. Plain x-rays demonstrated modiolus proximity of the electrode with the positioner. The new Clarion electrode with positioner is a relatively safe design for providing modiolus proximity. The electrophysiological benefits include reduction of threshold and power consumption.

Entities:  

Mesh:

Year:  2000        PMID: 11140987     DOI: 10.1177/0003489400109s1206

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol Suppl        ISSN: 0096-8056


  4 in total

1.  Cochlear Histopathology as Observed in Two Patients With a Cochlear Implant Electrode With Positioner.

Authors:  Takefumi Kamakura; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2016-07       Impact factor: 2.311

Review 2.  [Intraoperative audiological-technical diagnostics during cochlear implant surgery].

Authors:  T Wesarg; S Arndt; A Aschendorff; R Laszig; S Zirn
Journal:  HNO       Date:  2014-10       Impact factor: 1.284

3.  Histopathology of the Clarion cochlear implant electrode positioner in a human subject.

Authors:  M Seyyedi; B J Burgess; D K Eddington; B J Gantz; J B Nadol
Journal:  Audiol Neurootol       Date:  2013-06-14       Impact factor: 1.854

4.  Silastic Electrode Positioner Extrusion as a Late Complication of Cochlear Implantation Surgery.

Authors:  Masoud Motasaddi Zarandy; Saman Rezaeian; Mina Motasaddizarandy
Journal:  J Int Adv Otol       Date:  2022-07       Impact factor: 1.316

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.