Literature DB >> 11138301

Reduction of radiation exposure in the cardiac electrophysiology laboratory.

F H Wittkampf1, E F Wever, K Vos, J Geleijns, M J Schalij, J van der Tol, E O Robles de Medina.   

Abstract

The purpose of this study was to determine the effects of various protective measures on patient and operator radiation dose levels in catheter ablation procedures. Catheter ablation procedures are associated with significant radiation levels. The patient's skin and operator radiation levels were measured (1) at baseline, (2) after primary beam filtration by 0.3-mm copper sheet and 2-mm aluminium plate and implementation of the LocaLisa system, and (3) after reduction of the left anterior oblique fluoroscopic pulse rate and installation of a lead glass screen. Additionally, a comparative analysis of radiation exposure levels was performed in the seven Dutch catheter ablation centers. Filtration of both primary beams resulted in a more than two-fold reduction in patient skin dose. Together with the LocaLisa system, this resulted in a six-fold reduction in patient and operator dose. As expected, lowering of the left anterior oblique pulse rate from 25 to 12.5 Hz reduced the corresponding patient skin dose with a factor 2 while the lead-glass protection caused an extra factor 2 reduction for the operator. Large differences were observed between fluoroscopy systems used for catheter ablation in the Netherlands. Depending on patient body mass and fluoroscopy system, patient skin dose varied between 0.2 and 8.4 Gy/hour. Proper measures may allow for a significant reduction of patient and operator radiation exposure in catheter ablation procedures. The large influence of body mass and equipment on patient's skin dose requires a more direct monitoring of skin dose than total fluoroscopy time.

Entities:  

Mesh:

Year:  2000        PMID: 11138301     DOI: 10.1046/j.1460-9592.2000.01638.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  10 in total

Review 1.  Telomerase-independent mechanisms of telomere elongation.

Authors:  H Biessmann; J M Mason
Journal:  Cell Mol Life Sci       Date:  2003-11       Impact factor: 9.261

2.  Use of a non-fluoroscopic catheter navigation system for pulmonary vein isolation.

Authors:  Mark A Wood; Paul J Christman; Richard K Shepard; Kenneth A Ellenbogen
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

3.  The effect of NavX on fluoroscopy times in pediatric catheter ablation.

Authors:  Wilson Kwong; Andrea L Neilson; Christine C Chiu; Gil J Gross; Robert M Hamilton; Luc Soucie; Elizabeth A Stephenson; Joel A Kirsh
Journal:  J Interv Card Electrophysiol       Date:  2011-10-18       Impact factor: 1.900

Review 4.  New mapping technologies: an overview with a clinical perspective.

Authors:  Vias Markides; D Wyn Davies
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

5.  A family of intracardiac ultrasound imaging devices designed for guidance of electrophysiology ablation procedures.

Authors:  David J Sahn; Douglas N Stephens; Jonathan M Cannata; K Shung; Omer Oralkan; Amin Nikoozadeh; B T Pierre Khuri-Yakub; Hien Nguyen; Peter Chen; Aaron M Dentinger; Douglas Wildes; Kai E Thomenius; Aman Mahajan; Kalyanam Shivkumar; Matthew O'Donnell
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

Review 6.  Catheter ablation of ventricular tachycardia. From indication to three-dimensional mapping technology.

Authors:  Lars Eckardt; Günter Breithardt
Journal:  Herz       Date:  2009-05       Impact factor: 1.443

7.  Impact of a comprehensive safety program on radiation exposure during catheter ablation of atrial fibrillation: a prospective study.

Authors:  Dhanunjaya Lakkireddy; George Nadzam; Atul Verma; Subramanya Prasad; Kay Ryschon; Luigi Di Biase; Mohammed Khan; David Burkhardt; Robert Schweikert; Andrea Natale
Journal:  J Interv Card Electrophysiol       Date:  2008-11-06       Impact factor: 1.900

8.  Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

Authors:  D N Stephens; J Cannata; Ruibin Liu; Jian Zhong Zhao; K K Shung; Hien Nguyen; R Chia; A Dentinger; D Wildes; K E Thomenius; A Mahajan; K Shivkumar; Kang Kim; M O'Donnell; A Nikoozadeh; O Oralkan; P T Khuri-Yakub; D J Sahn
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

9.  Optimized Fluoroscopy Setting and Appropriate Project Position Can Reduce X-ray Radiation Doses Rates during Electrophysiology Procedures.

Authors:  Bing-Bo Hou; Yan Yao; Ling-Min Wu; Yu Qiao; Li-Hui Zheng; Li-Gang Ding; Gang Chen; Shu Zhang
Journal:  Chin Med J (Engl)       Date:  2015-05-05       Impact factor: 2.628

10.  Radiofrequency ablation without the use of fluoroscopy - in what kind of patients is it feasible?

Authors:  Edward Koźluk; Marcin Gawrysiak; Agnieszka Piątkowska; Piotr Lodziński; Marek Kiliszek; Sylwia Małkowska; Rajmund Zaczek; Radosław Piątkowski; Grzegorz Opolski; Dariusz Kozłowski
Journal:  Arch Med Sci       Date:  2013-11-05       Impact factor: 3.318

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.