Literature DB >> 11137841

Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography.

S Schalla1, E Nagel, H Lehmkuhl, C Klein, A Bornstedt, B Schnackenburg, U Schneider, E Fleck.   

Abstract

This study analyzes the accuracy of a new real-time magnetic resonance imaging (MRI) technique (acquisition duration, 62 ms/image) and echocardiography for the determination of left ventricular (LV) end-diastolic volume, end-systolic volume, ejection fraction, and muscle mass when compared with turbo gradient echo imaging as the reference standard. Thirty-four patients were examined with digital echocardiography, standard, and real-time MRI. A close correlation was found between the results of real-time imaging and the reference standard for end-diastolic volume, end-systolic volume, and ejection fraction (r >0.95), with a lower correlation for LV muscle mass (r = 0.81). Correlations between echocardiography and the reference standard were lower for all parameters. Real-time MRI enables the acquisition of high-quality cine loops of the entire heart in minimal time without electrocardiographic triggering or breath holding. Thus, patient setup and scan time can be reduced considerably. Results are similar to the reference standard and superior to echocardiography for determining LV volumes and ejection fraction. This technique is a valid alternative to current approaches and can form the basis of every cardiac MRI examination.

Entities:  

Mesh:

Year:  2001        PMID: 11137841     DOI: 10.1016/s0002-9149(00)01279-0

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  24 in total

Review 1.  Magnetic resonance imaging in detection and functional assessment of coronary artery disease.

Authors:  Wojciech Mazur; Steffen Brucks; Stephen N Darty; Pairoj Rerkpattanapipat
Journal:  Curr Atheroscler Rep       Date:  2002-03       Impact factor: 5.113

2.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

3.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

Review 4.  Techniques for comprehensive two dimensional echocardiographic assessment of left ventricular systolic function.

Authors:  T H Marwick
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

5.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

6.  Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography.

Authors:  Tae Hoon Kim; Young Hoon Ryu; Jin Hur; Sang Jin Kim; Hyun Soo Kim; Byoung Wook Choi; Young Kim; Hyung Jung Kim
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

7.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

8.  Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes.

Authors:  M G Danilouchkine; J J M Westenberg; B P F Lelieveldt; J H C Reiber
Journal:  MAGMA       Date:  2005-01-28       Impact factor: 2.310

9.  Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm.

Authors:  Georg Mühlenbruch; Marco Das; Christian Hohl; Joachim E Wildberger; Daniel Rinck; Thomas G Flohr; Ralf Koos; Christian Knackstedt; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2005-12-22       Impact factor: 5.315

10.  Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

Authors:  Marcus Katoh; Harald P Kühl; Elmar Spuentrup; Claudia S A Lipke; Rolf W Günther; Arno Buecker
Journal:  Eur Radiol       Date:  2007-01-12       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.