Literature DB >> 11131205

Analysis of photoneutron spectra produced in medical accelerators.

C Ongaro1, A Zanini, U Nastasi, J Ródenas, G Ottaviano, C Manfredotti, K W Burn.   

Abstract

A complete method is presented for the evaluation of photoneutron spectra produced in linear accelerators for cancer radiotherapy. It consists of a computer simulation code based on the MCNP4B Monte Carlo code, in which the new routine GAMMAN was implemented, allowing the accurate study of photoneutron production in high Z elements. In addition an experimental method based on a passive bubble spectrometer allows direct measurements of the photoneutron spectrum at the patient plane, also under the photon beam. The results are presented both for a 15 MeV linac with a traditional collimator system and for an 18 MeV linac equipped with a multileaf collimator, used in conformational radiotherapy.

Entities:  

Mesh:

Year:  2000        PMID: 11131205     DOI: 10.1088/0031-9155/45/12/101

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  A new analytical formula for neutron capture gamma dose calculations in double-bend mazes in radiation therapy.

Authors:  Hosein Ghiasi; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2012-05-24

3.  Monte Carlo characterizations mapping of the (γ,n) and (n,γ) photonuclear reactions in the high energy X-ray radiation therapy.

Authors:  Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-31

4.  Safe bunker designing for the 18 MV Varian 2100 Clinac: a comparison between Monte Carlo simulation based upon data and new protocol recommendations.

Authors:  Manije Beigi; Fatemeh Afarande; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-17

Review 5.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

6.  Radiotherapy dose enhancement using BNCT in conventional LINACs high-energy treatment: Simulation and experiment.

Authors:  Katia Alikaniotis; Oscar Borla; Valeria Monti; Gianna Vivaldo; Alba Zanini; Gianrossano Giannini
Journal:  Rep Pract Oncol Radiother       Date:  2015-08-10

7.  A neutron track etch detector for electron linear accelerators in radiotherapy.

Authors:  Branko Vukovic; Dario Faj; Marina Poje; Maja Varga; Vanja Radolic; Igor Miklavcic; Ana Ivkovic; Josip Planinic
Journal:  Radiol Oncol       Date:  2010-03-18       Impact factor: 2.991

8.  Photoneutron spectrometry by novel multi-directional spherical neutron spectrometry system.

Authors:  Mehdi Sohrabi; Amir Hakimi
Journal:  Sci Rep       Date:  2021-02-05       Impact factor: 4.379

9.  A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.

Authors:  Mohammad Taghi Bahreyni Toossi; Marziyeh Behmadi; Mahdi Ghorbani; Hamid Gholamhosseinian
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

10.  Design and fabrication of a Nano-based neutron shield for fast neutrons from medical linear accelerators in radiation therapy.

Authors:  Younes Afkham; Asghar Mesbahi; Abdolali Alemi; Farhad Zolfagharpour; Nasrollah Jabbari
Journal:  Radiat Oncol       Date:  2020-05-11       Impact factor: 3.481

  10 in total