Literature DB >> 11128305

A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.

R Wang1, X A Li.   

Abstract

The AAPM TG-60 report has proposed various dose calculation parameters for intravascular brachytherapy (IVBT). These parameters include the dose rate constant (or the dose rate at a reference position for a beta-particle emitting source), the radial dose function, and the anisotropy function. In this work, we have used a modified EGS4 Monte Carlo system to calculate these parameters for the two most commonly used IVBT sources (the beta-particle emitting 90Sr/90Y source and the photon emitting 192Ir SS source). To ensure the calculation accuracy, the present calculation was compared with several measurements and calculations reported by other authors. Excellent agreement was found for the results with the photon source. For beta-particle source calculation, the present results for a variety of point sources agree very well with a previous work. The presently calculated radial dose functions for the 90Sr/90Y source are consistent with those of a published work for intermediate radial distances. The dose uniformity in the axial direction was also studied. The contributions of bremsstrahlung photons to total doses for the 90Sr/90Y beta source, and the influence of ignoring electron transport on calculated doses for the 192Ir SS photon source are discussed.

Mesh:

Substances:

Year:  2000        PMID: 11128305     DOI: 10.1118/1.1319374

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Monte Carlo dosimetric parameter study of a new (32)P brachytherapy source.

Authors:  Junxiang Wu; Jing Huang; Fengxiang Long; Chengkai Wang; Zhangwen Wu; Chengjun Gou
Journal:  Br J Radiol       Date:  2016-04-04       Impact factor: 3.039

2.  Monte Carlo dosimetry of a new (90)Y brachytherapy source.

Authors:  Wu Junxiang; You Shihu; Huang Jing; Long Fengxiang; Wang Chengkai; Wu Zhangwen; Hou Qing; Gou Chengjun
Journal:  J Contemp Brachytherapy       Date:  2015-10-30

3.  Monte Carlo dosimetry for a new 32P brachytherapy source using FLUKA code.

Authors:  Razieh Rajabi; Payvand Taherparvar
Journal:  J Contemp Brachytherapy       Date:  2019-02-28

4.  Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

Authors:  Javier Vijande; Domingo Granero; Jose Perez-Calatayud; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2012-03-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.