Literature DB >> 11121697

Analysis of the Look-Locker T(1) mapping sequence in dynamic contrast uptake studies: simulation and in vivo validation.

M Karlsson1, B Nordell.   

Abstract

An alternative to the pulse sequences at present used in dynamic contrast uptake MRI is the dynamic LL-EPI T(1) mapping method. This method generates T(1) estimates in a few seconds, thereby allowing dynamic studies. A particular advantage of the LL-EPI technique is that it provides the opportunity to generate spatial and temporal information about the paramagnetic contrast agent concentration independently of the inflow rate. This paper illustrates, by computer simulations, the accuracy of the estimated 1/T(1) value when using the LL-EPI technique in situations that are not supported by the model. The simulated situations not supported by the model are those in which the longitudinal and transversal relaxation rates change during the T(1) mapping. The most critical moment occurs during a bolus passage of contrast agent when the concentration gradient is large. The computer simulations of the LL-EPI T(1) mapping method in non-supported situations show that in normal perfused capillary tissue the error in the estimated 1/T(1) value is within the absolute error of 0.1 s(-1) in most simulated situations, although in a typical vessel the simulations do indicate that the stated absolute error tolerance of 0.5 s(-1) is exceeded relatively easily. However, this transgression can be rectified by a non-bolus injection of the contrast agent media.

Mesh:

Substances:

Year:  2000        PMID: 11121697     DOI: 10.1016/s0730-725x(00)00193-4

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Myocardial T1 mapping with MRI: comparison of look-locker and MOLLI sequences.

Authors:  Marcelo Souto Nacif; Evrim B Turkbey; Neville Gai; Saman Nazarian; Rob J van der Geest; Radwa A Noureldin; Christopher T Sibley; Martin Ugander; Songtao Liu; Andrew E Arai; João A C Lima; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2011-09-23       Impact factor: 4.813

2.  Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission.

Authors:  Michael Rasper; Jonathan Nadjiri; Alexandra S Sträter; Marcus Settles; Karl-Ludwig Laugwitz; Ernst J Rummeny; Armin M Huber
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-30       Impact factor: 2.357

Review 3.  Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer: Techniques and Clinical Applications.

Authors:  S Gaddikeri; R S Gaddikeri; T Tailor; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

4.  T1 Mapping in cardiomyopathy at cardiac MR: comparison with endomyocardial biopsy.

Authors:  Christopher T Sibley; Radwa A Noureldin; Neville Gai; Marcelo Souto Nacif; Songtao Liu; Evrim B Turkbey; James O Mudd; Rob J van der Geest; João A C Lima; Marc K Halushka; David A Bluemke
Journal:  Radiology       Date:  2012-10-22       Impact factor: 11.105

5.  Effects of T2 * on accuracy and precision of dynamic T1 measurements using the single reference variable flip angle method: a simulation study.

Authors:  Michael A Malmberg; Henrik Odéen; Dennis L Parker
Journal:  Med Phys       Date:  2022-02-15       Impact factor: 4.071

6.  Relationship between Myocardial Extracellular Space Expansion Estimated with Post-Contrast T1 Mapping MRI and Left Ventricular Remodeling and Neurohormonal Activation in Patients with Dilated Cardiomyopathy.

Authors:  Ji Hyun Yoon; Jung Woo Son; Hyemoon Chung; Chul Hwan Park; Young-Jin Kim; Hyuk-Jae Chang; Geu-Ru Hong; Tae Hoon Kim; Jong-Won Ha; Byoung Wook Choi; Se-Joong Rim; Namsik Chung; Eui-Young Choi
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

7.  Vascular disrupting agent in pancreatic and hepatic tumour allografts: observations of location-dependent efficacy by MRI, microangiography and histomorphology.

Authors:  Ting Yin; Yewei Liu; Ronald Peeters; Yuanbo Feng; Jie Yu; Uwe Himmelreich; Raymond Oyen; Yicheng Ni
Journal:  Br J Cancer       Date:  2017-09-14       Impact factor: 7.640

Review 8.  T1 Mapping for Myocardial Fibrosis by Cardiac Magnetic Resonance Relaxometry-A Comprehensive Technical Review.

Authors:  Christian R Hamilton-Craig; Mark W Strudwick; Graham J Galloway
Journal:  Front Cardiovasc Med       Date:  2017-03-16
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.