Literature DB >> 1111497

Myocardial injury from transthoracic defibrillator countershock.

E D Warner, C Dahl, G A Ewy.   

Abstract

Myocardial damage resulting from transthoracic administration of direct current with cardiac defilbrillators present in clinical use was studied in 66 dogs. Electrodes were applied to the thoracic skin. All direct current discharges were delivered via a commercially available defilbrillator. Most of the animals received ten consecutive discharges with a dial setting of 400 watt-seconds. Animals were killed from 3 to 14 days after receiving the discharges. Myocarial necrosis was produced in most of the animals. The lesions were characterized by sharply localized areas of muscle necrosis that progressed to fibrous scars. Mineralization of damaged muscle and florid proliferation of large mononuclear cells were striking features of the lesions.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1111497

Source DB:  PubMed          Journal:  Arch Pathol        ISSN: 0363-0153


  7 in total

1.  Cardioversion 125 times without necrosis.

Authors:  P A Cann; C F Corke
Journal:  Br Med J (Clin Res Ed)       Date:  1981-06-06

2.  Relationship between canine transthoracic impedance and defibrillation threshold. Evidence for current-based defibrillation.

Authors:  B B Lerman; H R Halperin; J E Tsitlik; K Brin; C W Clark; O C Deale
Journal:  J Clin Invest       Date:  1987-09       Impact factor: 14.808

Review 3.  Myocardial diseases of animals.

Authors:  J F Van Vleet; V J Ferrans
Journal:  Am J Pathol       Date:  1986-07       Impact factor: 4.307

4.  Initial experience with a microprocessor controlled current based defibrillator.

Authors:  G W Dalzell; S R Cunningham; J Anderson; A A Adgey
Journal:  Br Heart J       Date:  1989-06

5.  The nitric oxide synthase inhibitor N(G)-nitro-L-arginine decreases defibrillation-induced free radical generation.

Authors:  Craig B Clark; Yi Zhang; Sean M Martin; L Ray Davies; Linjing Xu; Kevin C Kregel; Francis J Miller; Garry R Buettner; Richard E Kerber
Journal:  Resuscitation       Date:  2004-03       Impact factor: 5.262

6.  Test of four defibrillation dosing strategies using a two-dimensional finite-element model.

Authors:  J L Lehr; I F Ramirez; W J Karlon; S R Eisenberg
Journal:  Med Biol Eng Comput       Date:  1992-11       Impact factor: 2.602

Review 7.  Paediatric cardiac catheterization: innovations.

Authors:  J J Javorski; D D Hansen; P C Laussen; M L Fox; J Lavoie; F A Burrows
Journal:  Can J Anaesth       Date:  1995-04       Impact factor: 5.063

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.