Literature DB >> 21104000

A novel medical image quality index.

Sheng-Chieh Lin1, You-Chen Lin, Weng-Song Feng, Jia-Ming Wu, Tzong-Jer Chen.   

Abstract

A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a medical image compression algorithm named JJ2000. Following that, the quality of the reconstructed images was evaluated using the grey relational coefficient calculation. The results were shown consistent with popular objective quality metrics. The impact of different image aspects on four grey relational coefficient methods were further tested. The results showed that these grey relational coefficients have different slopes but very high consistency for various image areas. Nagai's grey relational coefficient was chosen in this study because of higher calculation speed and sensitivity. A comparison was also made between this method and other windows-based objective metrics for various window sizes. Studies found that the grey relational coefficient results are less sensitive to window size changes. The performance of this index is better than some windows-based objective metrics and can be used as an image quality index.

Mesh:

Year:  2011        PMID: 21104000      PMCID: PMC3180531          DOI: 10.1007/s10278-010-9353-y

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  6 in total

1.  Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission.

Authors:  A Kalyanpur; V P Neklesa; C R Taylor; A R Daftary; J A Brink
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

2.  A novel image quality index using Moran I statistics.

Authors:  Tzong-Jer Chen; Keh-Shih Chuang; Jay Wu; Sharon C Chen; Ing-Ming Hwang; Meei-Ling Jan
Journal:  Phys Med Biol       Date:  2003-04-21       Impact factor: 3.609

3.  A statistical method for evaluation quality of medical images: a case study in bit discarding and image compression.

Authors:  Tzong-Jer Chen; Keh-Shih Chuang; Yuang-Chin Chiang; Jen-Hao Chang; Ren-Shyan Liu
Journal:  Comput Med Imaging Graph       Date:  2004-06       Impact factor: 4.790

4.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

5.  A blurring index for medical images.

Authors:  Tzong-Jer Chen; Keh-Shih Chuang; Jen-Hao Chang; Ya-Hui Shiao; Chun-Chao Chuang
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

6.  Quality of compressed medical images.

Authors:  Ya-Hui Shiao; Tzong-Jer Chen; Keh-Shih Chuang; Cheng-Hsun Lin; Chun-Chao Chuang
Journal:  J Digit Imaging       Date:  2007-02-22       Impact factor: 4.056

  6 in total
  1 in total

1.  Biomedical imaging informatics in the era of precision medicine: progress, challenges, and opportunities.

Authors:  William Hsu; Mia K Markey; May D Wang
Journal:  J Am Med Inform Assoc       Date:  2013 Nov-Dec       Impact factor: 4.497

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.