Literature DB >> 11100890

Recognition thresholds for letters with simulated dioptric blur.

H Akutsu1, H E Bedell, S S Patel.   

Abstract

We examined the effects of simulated dioptric blur on the degradation of visual acuity using digitally filtered letters. Four types of digital filters were applied to 5 letters (C, D, E, O, and S), constructed to the specifications of Sloan optotypes. These filters were: (1) "normal," designed to simulate the positive and negative lobes of the modulation transfer function (MTF) produced by dioptric blur; (2) "truncated," which passed only those spatial frequencies up to the first zero of the MTF; (3) "phase-rectified," which inverted all of the negative lobes of the MTF to positive; and (4) "truncated-plus-negative," which eliminated all positive lobes above the first zero of the MTF. The letter size required to achieve 60%-correct identification was determined for letters that were filtered to simulate +1, +2, and +4 D of blur. Letters subjected to normal, truncated, and truncated-plus-negative filtering had approximately the same acuity threshold, whereas the threshold size for phase-rectified letters was significantly better. Our interpretation of these results is that dioptric blur hinders letter recognition because useful spatial frequency information is limited to that below the first zero of the MTF, and not because of interference from the phase-reversed spatial frequency information above the first zero. Our letter identification thresholds are consistent with recent evidence that the critical information for letter acuity corresponds to approximately 1.5 cycles/letter.

Mesh:

Year:  2000        PMID: 11100890     DOI: 10.1097/00006324-200010000-00006

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  The effect of dioptric blur on reading performance.

Authors:  Susana T L Chung; Samuel H Jarvis; Sing-Hang Cheung
Journal:  Vision Res       Date:  2007-04-17       Impact factor: 1.886

2.  Resolution acuity versus recognition acuity with Landolt-style optotypes.

Authors:  Sven P Heinrich; Michael Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-05       Impact factor: 3.117

3.  Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors.

Authors:  Ayeswarya Ravikumar; Jason D Marsack; Harold E Bedell; Yue Shi; Raymond A Applegate
Journal:  J Vis       Date:  2013-11-26       Impact factor: 2.240

4.  Impact of pupil transmission apodization on presbyopic through-focus visual performance with spherical aberration.

Authors:  Len Zheleznyak; HaeWon Jung; Geunyoung Yoon
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-03       Impact factor: 4.799

5.  The effect of astigmatic axis on visual acuity measured with different alphabets in Roman alphabet readers.

Authors:  Pedro M Serra; Michael J Cox; Catharine M Chisholm
Journal:  Clin Optom (Auckl)       Date:  2018-08-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.