Literature DB >> 11098918

Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography.

J H Kim1, Y Choi, K S Joo, B S Sihn, J W Chong, S E Kim, K H Lee, Y S Choe, B T Kim.   

Abstract

We have developed a small scintillation camera dedicated to breast imaging and have evaluated the performance of the system. In order to increase the limited field of view (FOV) determined by the size of a position-sensitive photomultiplier tube (PSPMT), the imaging characteristics of a diverging hole collimator (DHC) were also investigated. The small scintillation camera system consists of an NaI(Tl) crystal (60 mm x 60 mm x 6 mm) coupled to a Hamamatsu R3941 PSPMT, a resistor chain circuit, preamplifiers, nuclear instrument modules, an analogue to digital converter and a PC for control and display. The intrinsic energy resolution of the system was 12.9% FWHM at 140 keV. The spatial resolution was measured using a line-slit mask and 99mTc point sources and was 3.1 mm FWHM. The intrinsic sensitivity of the system was approximately 162 counts/s kBq(-1). The DHC made it possible to image a larger FOV (75 x 75 mm2 at the surface of collimator) than a parallel-hole collimator (60 x 60 mm2). The system sensitivity obtained using the DHC gradually decreased with distance (3% at 1 cm, 6% at 2 cm and 9% at 3 cm). The results demonstrate that the system developed in this study could be utilized clinically to image malignant breast tumours. A DHC can be employed to expand the FOV of the system confined by the size of PSPMT with a modest compromise in the performance of the system.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11098918     DOI: 10.1088/0031-9155/45/11/326

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera.

Authors:  Aya Abe; Nobukazu Takahashi; Jin Lee; Takashi Oka; Kazuya Shizukuishi; Tatsuya Kikuchi; Tomio Inoue; Masao Jimbo; Hideki Ryuo; Chris Bickel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-03       Impact factor: 9.236

Review 2.  Nuclear imaging of the breast: translating achievements in instrumentation into clinical use.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

3.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Authors:  Caryl N Brzymialkiewicz; Martin P Tornai; Randolph L McKinley; James E Bowsher
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

4.  Quantification of lesion size, depth, and uptake using a dual-head molecular breast imaging system.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  Scientific Impact Recognition Award: Molecular breast imaging: a review of the Mayo Clinic experience.

Authors:  Carrie B Hruska; Judy C Boughey; Stephen W Phillips; Deborah J Rhodes; Dietlind L Wahner-Roedler; Dana H Whaley; Amy C Degnim; Michael K O'Connor
Journal:  Am J Surg       Date:  2008-08-23       Impact factor: 2.565

6.  Molecular breast imaging: use of a dual-head dedicated gamma camera to detect small breast tumors.

Authors:  Carrie B Hruska; Stephen W Phillips; Dana H Whaley; Deborah J Rhodes; Michael K O'Connor
Journal:  AJR Am J Roentgenol       Date:  2008-12       Impact factor: 3.959

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.