Sensitivity of two electron beam tomography protocols for the detection and quantification of coronary artery calcium.

T Callister1, W Janowitz, P Raggi.   

Abstract

OBJECTIVE: The purpose of this study was to compare the sensitivity of two electron beam tomography protocols for detection and quantification of coronary artery calcium. SUBJECTS AND METHODS: We selected 101 patients (57% men, mean age 53 +/- 10 years) to undergo two consecutive electron beam tomography and acquired imaging with both a 6-mm and a 3-mm slicing protocol. Three pixels (area, 1.03 mm(2)) and a minimal density of 130 H were used for definition of calcified plaque.
RESULTS: We found coronary artery calcifications in 46 patients when we used a 6-mm protocol and in 61 patients when we used a 3-mm protocol (p < 0.001). The average total calcium score was 77 (+/-140) with a 6-mm protocol and 251 (+/-395) with a 3-mm protocol (p < 0.005). The average number of calcified lesions per patient was 1.7 for a 6-mm protocol and 3.7 for a 3-mm protocol (p < 0.01). Of 179 individual lesions seen using a 3-mm protocol, 103 (58%) were missed using a 6-mm protocol, and only 27% of the lesions with a calcium score less than or equal to 40 seen with a 3-mm protocol were detected with 6-mm slicing (p < 0.001). The mean lesion attenuation with a 6-mm protocol was 160 (+/-42) H, compared with 218 (+/-44) H with a 3-mm protocol (p < 0.001), indicating a significantly greater partial volume averaging with the former protocol.
CONCLUSION: A 6-mm slicing protocol is significantly less sensitive than a 3-mm protocol for the detection and quantification of coronary artery calcium. Since one third of coronary events occur in patients with low calcium scores, a 6-mm protocol might be unreliable for risk assessment because of substantial loss of information in this calcium score range.

Entities:  

Mesh:

Year:  2000        PMID: 11090414     DOI: 10.2214/ajr.175.6.1751743

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Variability of repeated coronary artery calcium measurements by 1.25-mm- and 2.5-mm-thickness images on prospective electrocardiograph-triggered 64-slice CT.

Authors:  Jun Horiguchi; Noriaki Matsuura; Hideya Yamamoto; Nobuhiko Hirai; Masao Kiguchi; Chikako Fujioka; Toshiro Kitagawa; Nobuoki Kohno; Katsuhide Ito
Journal:  Eur Radiol       Date:  2007-08-03       Impact factor: 5.315

2.  Detection of small vessels with electron beam computed tomographic angiography using 1.5 and 3 mm collimator protocols.

Authors:  Songshou Mao; Jerold S Shinbane; Ronald J Oudiz; Ferdinand Flores; Alex Chau; Stephen Liu; Shaojun Wang; Yanlin Gao; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2005-07-23       Impact factor: 2.357

Review 3.  Update on using coronary calcium screening by computed tomography to measure risk for coronary heart disease.

Authors:  Brad H Thompson; William Stanford
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

Review 4.  Subclinical cardiovascular disease assessment in persons with diabetes.

Authors:  Haider Javed Warraich; Khurram Nasir
Journal:  Curr Cardiol Rep       Date:  2013-05       Impact factor: 2.931

Review 5.  Coronary calcium screening and coronary risk stratification.

Authors:  Paolo Raggi; George James
Journal:  Curr Atheroscler Rep       Date:  2004-03       Impact factor: 5.113