Literature DB >> 11077404

Influence of inflammatory cells and serum on the performance of implantable glucose sensors.

M Gerritsen1, J A Jansen, A Kros, D M Vriezema, N A Sommerdijk, R J Nolte, J A Lutterman, S W Van Hövell, A Van der Gaag.   

Abstract

The objective of this investigation was to evaluate the influence of polymorphonuclear granulocytes on the performance of uncoated and cellulose acetate/Nafion coated amperometric glucose sensors in vitro. The response of these sensors was also investigated in serum. Uncoated and coated sensors showed lower sensitivities to glucose, with a significant drift in sensor output upon exposure to serum or leukocytes. Although the use of a coating resulted in higher sensitivity, the progressive loss of output was not completely prevented. Stimulated granulocytes were shown to excrete components, probably catalase and myeloperoxidase, which consumed the hydrogen peroxide formed by the oxidation of glucose. In addition, adsorbed serum proteins formed a diffusional barrier for glucose. Furthermore, serum was found to contain low-molecular weight components that alone inhibited glucose oxidase activity. Based on preliminary electrochemical results, we postulate that rabbit serum contains oxidizing substrates that compete with molecular oxygen for the acceptance of electrons from the oxidized enzyme. Consequently, future efforts should be aimed at elucidating the mechanisms involved in the interference of unknown serum components with electron transfer. In addition, further investigations have to be performed to develop an outer membrane that minimizes protein adsorption as well as the actions of inflammatory cells. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11077404     DOI: 10.1002/1097-4636(200101)54:1<69::aid-jbm8>3.0.co;2-q

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  26 in total

1.  Glucose sensor membranes for mitigating the foreign body response.

Authors:  Ahyeon Koh; Scott P Nichols; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

Review 2.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

Review 3.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

4.  Blood-induced interference of glucose sensor function in vitro: implications for in vivo sensor function.

Authors:  Ulrike Klueh; Zenghe Liu; Tianmei Ouyang; Brian Cho; Ben Feldman; Timothy P Henning; Don Kreutzer
Journal:  J Diabetes Sci Technol       Date:  2007-11

Review 5.  Biomaterials/tissue interactions: possible solutions to overcome foreign body response.

Authors:  Jacqueline M Morais; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2010-02-09       Impact factor: 4.009

6.  A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response.

Authors:  Yoshinori Onuki; Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11

7.  Glucose Sensing in the Subcutaneous Tissue: Attempting to Correlate the Immune Response with Continuous Glucose Monitoring Accuracy.

Authors:  Jeffrey I Joseph; Gabriella Eisler; David Diaz; Abdurizzagh Khalf; Channy Loeum; Marc C Torjman
Journal:  Diabetes Technol Ther       Date:  2018-05       Impact factor: 6.118

8.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.

Authors:  Ulrike Klueh; Jackman T Frailey; Yi Qiao; Omar Antar; Donald L Kreutzer
Journal:  Biomaterials       Date:  2014-01-22       Impact factor: 12.479

View more