Literature DB >> 11062361

Parallel plate model for trabecular bone exhibits volume fraction-dependent bias.

J S Day1, M Ding, A Odgaard, D R Sumner, I Hvid, H Weinans.   

Abstract

Unbiased stereological methods were used in conjunction with microcomputed tomographic (micro-CT) scans of human and animal bone to investigate errors created when the parallel plate model was used to calculate morphometric parameters. Bone samples were obtained from the human proximal tibia, canine distal femur, rat tail, and pig spine and scanned in a micro-CT scanner. Trabecular thickness, trabecular spacing, and trabecular number were calculated using the parallel plate model. Direct thickness, and spacing and connectivity density were calculated using unbiased three-dimensional methods. Both thickness and spacing calculated using the plate model were well correlated to the direct three-dimensional measures (r(2) = 0. 77-0.92). The correlation between trabecular number and connectivity density varied greatly (r(2) = 0.41-0.94). Whereas trabecular thickness was consistently underestimated using the plate model, trabecular spacing was underestimated at low volume fractions and overestimated at high volume fractions. Use of the plate model resulted in a volume-dependent bias in measures of thickness and spacing (p < 0.001). This was a result of the fact that samples of low volume fraction were much more "rod-like" than those of the higher volume fraction. Our findings indicate that the plate model provides biased results, especially when populations with different volume fractions are compared. Therefore, we recommend direct thickness measures when three-dimensional data sets are available.

Entities:  

Mesh:

Year:  2000        PMID: 11062361     DOI: 10.1016/s8756-3282(00)00371-9

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  16 in total

Review 1.  Effects of microarchitecture on bone strength.

Authors:  Jacqueline C van der Linden; Harrie Weinans
Journal:  Curr Osteoporos Rep       Date:  2007-06       Impact factor: 5.096

2.  Resolution dependence of the non-metric trabecular structure indices.

Authors:  Miki Sode; Andrew J Burghardt; Robert A Nissenson; Sharmila Majumdar
Journal:  Bone       Date:  2007-12-23       Impact factor: 4.398

3.  Mechanical loading causes detectable changes in morphometric measures of trabecular structure in human cancellous bone.

Authors:  Yener N Yeni; Brenda Wu; Lily Huang; Daniel Oravec
Journal:  J Biomech Eng       Date:  2013-05       Impact factor: 2.097

4.  The adaption of the bony microstructure of the human glenoid cavity as a result of long-term biomechanical loading.

Authors:  Sebastian Hoechel; Tibor Andrea Zwimpfer; Mireille Toranelli; Magdalena Müller-Gerbl
Journal:  Surg Radiol Anat       Date:  2019-02-01       Impact factor: 1.246

5.  BoneJ: Free and extensible bone image analysis in ImageJ.

Authors:  Michael Doube; Michał M Kłosowski; Ignacio Arganda-Carreras; Fabrice P Cordelières; Robert P Dougherty; Jonathan S Jackson; Benjamin Schmid; John R Hutchinson; Sandra J Shefelbine
Journal:  Bone       Date:  2010-09-15       Impact factor: 4.398

6.  Variability of trabecular microstructure is age-, gender-, race- and anatomic site-dependent and affects stiffness and stress distribution properties of human vertebral cancellous bone.

Authors:  Yener N Yeni; Matthew J Zinno; Janardhan S Yerramshetty; Roger Zauel; David P Fyhrie
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

7.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

8.  Micro-CT and mechanical evaluation of subchondral trabecular bone structure between postmenopausal women with osteoarthritis and osteoporosis.

Authors:  Z-M Zhang; Z-C Li; L-S Jiang; S-D Jiang; L-Y Dai
Journal:  Osteoporos Int       Date:  2009-09-22       Impact factor: 4.507

9.  Age-related changes in vertebral and iliac crest 3D bone microstructure--differences and similarities.

Authors:  J S Thomsen; M V Jensen; A S Niklassen; E N Ebbesen; A Brüel
Journal:  Osteoporos Int       Date:  2014-08-28       Impact factor: 4.507

10.  Cancellous bone properties and matrix content of TGF-beta2 and IGF-I in human tibia: a pilot study.

Authors:  Yener N Yeni; X Neil Dong; Bingbing Zhang; Gary J Gibson; David P Fyhrie
Journal:  Clin Orthop Relat Res       Date:  2009-05-27       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.