Literature DB >> 11057530

Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device.

A F Mannion1, G N Klein, J Dvorak, C Lanz.   

Abstract

Range of motion tests are often employed in the quantification of musculoskeletal impairment and in the assessment of the efficacy of therapeutic interventions. The aim of the present study was to compare the absolute values for, and the day-to-day reliability of, measures of cervical spinal mobility made with two computerised motion analysis devices. The ranges of cervical flexion, extension, lateral bending, axial rotation, and axial rotation in flexion and extension were determined for 19 volunteers using both the CA6000 Spine Motion Analyser and the Zebris CMS system; all measures were repeated on a second occasion 1-3 days later. The test-retest reliability was good for each instrument: there was no significant difference between the mean values derived on the two separate days (P>0.05), and the corresponding intraclass correlation coefficients were 0.75-0.93 for all pri-O mary movements and 0.57-0.93 for axial rotation in flexion or in extension. For each primary movement, a small but significant difference (1-10%; P<0.05) between the values derived from the two instruments was observed, the systematic nature of which was revealed by the excellent correlation coefficients between them. For the measures of axial rotation in flexion or in extension, however, there was not only a poor correlation between the data obtained from the two devices, but the mean values also differed significantly. Each device is highly reliable in itself and can be used with confidence in longitudinal studies. The establishment of 'normal' values for the primary motions should take account of the slight differences observed between devices. Normal values for rotation in flexion or extension cannot be established until the source of the device-dependent difference is identified.

Entities:  

Mesh:

Year:  2000        PMID: 11057530      PMCID: PMC3611373          DOI: 10.1007/s005860000187

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  9 in total

1.  Soccer causes degenerative changes in the cervical spine.

Authors:  Alparslan Kartal; Ibrahim Yildiran; Alparslan Senköylü; Feza Korkusuz
Journal:  Eur Spine J       Date:  2003-11-28       Impact factor: 3.134

2.  The influence of age, anthropometrics and range of motion on the morphometry of the synovial folds of the lateral atlanto-axial joints: a pilot study.

Authors:  Alexandra Webb; Angela Darekar; Hamid Rassoulian
Journal:  Eur Spine J       Date:  2010-08-14       Impact factor: 3.134

3.  Effects of back posture education on elementary schoolchildren's back function.

Authors:  Elisabeth Geldhof; Greet Cardon; Ilse De Bourdeaudhuij; Lieven Danneels; Pascal Coorevits; Guy Vanderstraeten; Dirk De Clercq
Journal:  Eur Spine J       Date:  2006-08-30       Impact factor: 3.134

4.  Neck range of motion measurements using a new three-dimensional motion analysis system: validity and repeatability.

Authors:  Haruhi Inokuchi; Michio Tojima; Hiroshi Mano; Yuki Ishikawa; Naoshi Ogata; Nobuhiko Haga
Journal:  Eur Spine J       Date:  2015-04-07       Impact factor: 3.134

5.  Co-occurrence of outlet impingement syndrome of the shoulder and restricted range of motion in the thoracic spine--a prospective study with ultrasound-based motion analysis.

Authors:  Christina Theisen; Ad van Wagensveld; Nina Timmesfeld; Turgay Efe; Thomas J Heyse; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-06-29       Impact factor: 2.362

6.  Inter-individual variation in vertebral kinematics affects predictions of neck musculoskeletal models.

Authors:  Derek D Nevins; Liying Zheng; Anita N Vasavada
Journal:  J Biomech       Date:  2014-09-01       Impact factor: 2.712

Review 7.  Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review.

Authors:  Chantal H P de Koning; Sylvia P van den Heuvel; J Bart Staal; Bouwien C M Smits-Engelsman; Erik J M Hendriks
Journal:  Eur Spine J       Date:  2008-04-22       Impact factor: 3.134

8.  The effects of the Mulligan Sustained Natural Apophyseal Glide (SNAG) mobilisation in the lumbar flexion range of asymptomatic subjects as measured by the Zebris CMS20 3-D motion analysis system.

Authors:  Maria Moutzouri; Evdokia Billis; Nikolaos Strimpakos; Polixeni Kottika; Jacqueline A Oldham
Journal:  BMC Musculoskelet Disord       Date:  2008-10-01       Impact factor: 2.362

9.  Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer.

Authors:  Kerstin Luedtke; Thomas Schoettker-Königer; Toby Hall; Christine Reimer; Maike Grassold; Petra Hasselhoff-Styhler; Christian Neulinger; Max Obrocki; Philipp Przyhoda; Axel Schäfer
Journal:  BMC Musculoskelet Disord       Date:  2020-08-11       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.