Performance characteristics of the 3-D OSEM algorithm in the reconstruction of small animal PET images. Ordered-subsets expectation-maximixation.

R Yao1, J Seidel, C A Johnson, M E Daube-Witherspoon, M V Green, R E Carson.   

Abstract

Rat brain images acquired with a small animal positron emission tomography (PET) camera and reconstructed with the three-dimensional (3-D) ordered-subsets expectation-maximization (OSEM) algorithm with resolution recovery have better quality when the brain is imaged by itself than when inside the head with surrounding background activity. The purpose of this study was to characterize the dependence of this effect on the level of background activity, attenuation, and scatter. Monte Carlo simulations of the imaging system were performed. The coefficient of variation from replicate images, full-width at half-maximum (FWHM) from point sources and image profile fitting, and image contrast and uniformity were used to evaluate algorithm performance. A rat head with the typical levels of five and ten times the brain activity in the surrounding background requires additional iterations to achieve the same resolution as the brain-only case at a cost of 24% and 64% additional noise, respectively. For the same phantoms, object scatter reduced contrast by 3%-5%. However, attenuation degraded resolution by 0.2 mm and was responsible for up to 12% nonuniformity in the brain images suggesting that attenuation correction is useful. Given the effects of emission and attenuation distribution on both resolution and noise, simulations or phantom studies should be used for each imaging situation to select the appropriate number of OSEM iterations to achieve the desired resolution-noise levels.

Entities:  

Mesh:

Year:  2000        PMID: 11055803     DOI: 10.1109/42.876305

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  17 in total

1.  Imaging of the muscarinic acetylcholine neuroreceptor in rats with the M2 selective agonist [18F]FP-TZTP.

Authors:  Laura Ravasi; Joji Tokugawa; Toshiyuki Nakayama; Jurgen Seidel; Louis Sokoloff; William C Eckelman; Dale O Kiesewetter
Journal:  Nucl Med Biol       Date:  2011-08-09       Impact factor: 2.408

2.  On the assessment of spatial resolution of PET systems with iterative image reconstruction.

Authors:  Kuang Gong; Simon R Cherry; Jinyi Qi
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

3.  Assessment of a three-dimensional line-of-response probability density function system matrix for PET.

Authors:  Rutao Yao; Ranjith M Ramachandra; Neeraj Mahajan; Vinay Rathod; Noel Gunasekar; Ashish Panse; Tianyu Ma; Yiqiang Jian; Jianhua Yan; Richard E Carson
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

4.  Influence of the partial volume correction method on (18)F-fluorodeoxyglucose brain kinetic modelling from dynamic PET images reconstructed with resolution model based OSEM.

Authors:  Spencer L Bowen; Larry G Byars; Christian J Michel; Daniel B Chonde; Ciprian Catana
Journal:  Phys Med Biol       Date:  2013-09-20       Impact factor: 3.609

5.  Distribution of the 5-HT(1A) receptor antagonist [ (18)F]FPWAY in blood and brain of the rat with and without isoflurane anesthesia.

Authors:  Joji Tokugawa; Laura Ravasi; Toshiyuki Nakayama; Lixin Lang; Kathleen C Schmidt; Jurgen Seidel; Michael V Green; Louis Sokoloff; William C Eckelman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-09-22       Impact factor: 9.236

6.  The impact of iterative reconstruction protocol, signal-to-background ratio and background activity on measurement of PET spatial resolution.

Authors:  Sahar Rezaei; Pardis Ghafarian; Mehrdad Bakhshayesh-Karam; Carlos F Uribe; Arman Rahmim; Saeed Sarkar; Mohammad Reza Ay
Journal:  Jpn J Radiol       Date:  2020-01-01       Impact factor: 2.374

7.  Antiretroviral tissue kinetics: in vivo imaging using positron emission tomography.

Authors:  Michele Di Mascio; Sharat Srinivasula; Abesh Bhattacharjee; Lily Cheng; Lucia Martiniova; Peter Herscovitch; Juan Lertora; Dale Kiesewetter
Journal:  Antimicrob Agents Chemother       Date:  2009-08-10       Impact factor: 5.191

8.  Performance evaluation of an Inveon PET preclinical scanner.

Authors:  Cristian C Constantinescu; Jogeshwar Mukherjee
Journal:  Phys Med Biol       Date:  2009-04-21       Impact factor: 3.609

9.  Animal PET for thioacetamide-induced rat cholangiocarcinoma: a novel and reliable platform.

Authors:  Chun-Nan Yeh; Kun-Ju Lin; Ing-Tsung Hsiao; Tzu-Chen Yen; Tsung-Wen Chen; Yi-Yin Jan; Yi-Hsiu Chung; Chung-Fu Lin; Miin-Fu Chen
Journal:  Mol Imaging Biol       Date:  2008-05-20       Impact factor: 3.488

10.  Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards.

Authors:  Qinan Bao; Danny Newport; Mu Chen; David B Stout; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057