Literature DB >> 11050637

Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method.

J M Chia1, S E Fischer, S A Wickline, C H Lorenz.   

Abstract

In many cardiac patients, image quality and/or scan efficiency is reduced due to imprecise R-wave ability to trigger the scan due to noise on the electrocardiogram (ECG) caused by the magnetic resonance (MR) environment. We developed a triggering system that uses the spatial information of the vectorcardiogram (VCG) to minimize the effects of MR-related noise on triggering. Fifteen volunteers underwent standard cardiovascular MR exams, and a total of 52,474 R-waves were evaluated with the algorithm, giving a performance index of 99.91%. The mean propagation delay of the system was -10.64 +/- 3.19 msec, which falls within the real-time definition for cardiac MRI triggering. Five patients had arrhythmias consisting of premature ventricular depolarizations (PVDs) and supraventricular extra systoles. For those patients with PVDs, all arrhythmic beats were rejected unless they passed through the algorithm's reference point. The performance index for the arrhythmic patients approached 100%. VCG-based triggering has been demonstrated to provide near 100% triggering performance during cardiac MR examinations.

Entities:  

Mesh:

Year:  2000        PMID: 11050637     DOI: 10.1002/1522-2586(200011)12:5<678::aid-jmri4>3.0.co;2-5

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  26 in total

Review 1.  Review of new techniques in echocardiography and magnetic resonance imaging as applied to patients with congenital heart disease.

Authors:  D J Sahn; G W Vick
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

Review 2.  Magnetic resonance imaging assessment of cardiac function.

Authors:  W Gregory Hundley; Craig A Hamilton; Pairoj Rerkpattanapipat
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

3.  Theta power during encoding predicts subsequent-memory performance and default mode network deactivation.

Authors:  Thomas P White; Marije Jansen; Kathrin Doege; Karen J Mullinger; S Bert Park; Elizabeth B Liddle; Penny A Gowland; Susan T Francis; Richard Bowtell; Peter F Liddle
Journal:  Hum Brain Mapp       Date:  2012-06-19       Impact factor: 5.038

4.  Adaptive removal of gradients-induced artefacts on ECG in MRI: a performance analysis of RLS filtering.

Authors:  Mario Sansone; Luciano Mirarchi; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-03-18       Impact factor: 2.602

5.  Color-encoded semiautomatic analysis of multi-slice first-pass magnetic resonance perfusion: comparison to tetrofosmin single photon emission computed tomography perfusion and X-ray angiography.

Authors:  Holger Thiele; Sven Plein; Marcel Breeuwer; John P Ridgway; David Higgins; Penelope J Thorley; Gerhard Schuler; Mohan U Sivananthan
Journal:  Int J Cardiovasc Imaging       Date:  2004-10       Impact factor: 2.357

6.  Best current practice for obtaining high quality EEG data during simultaneous FMRI.

Authors:  Karen J Mullinger; Pierluigi Castellone; Richard Bowtell
Journal:  J Vis Exp       Date:  2013-06-03       Impact factor: 1.355

7.  Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T.

Authors:  Meike Becker; Tobias Frauenrath; Fabian Hezel; Gabriele A Krombach; Ute Kremer; Benedikt Koppers; Christoph Butenweg; Andreas Goemmel; Jane F Utting; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2009-12-16       Impact factor: 5.315

8.  Adaptive step size LMS improves ECG detection during MRI at 1.5 and 3 T.

Authors:  André Guillou; Jean-Marc Sellal; Sarah Ménétré; Grégory Petitmangin; Jacques Felblinger; Laurent Bonnemains
Journal:  MAGMA       Date:  2017-06-19       Impact factor: 2.310

9.  Feasibility and diagnostic accuracy of whole heart coronary MR angiography using free-breathing 3D balanced turbo-field-echo with SENSE and the half-fourier acquisition technique.

Authors:  Young Jin Kim; Jae-Seung Seo; Byoung Wook Choi; Kyu Ok Choe; Yangsoo Jang; Young-Guk Ko
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

10.  Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla.

Authors:  Tobias Frauenrath; Fabian Hezel; Wolfgang Renz; Thibaut de Geyer d'Orth; Matthias Dieringer; Florian von Knobelsdorff-Brenkenhoff; Marcel Prothmann; Jeanette Schulz Menger; Thoralf Niendorf
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-16       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.