Literature DB >> 27605033

Thin film based semi-active resonant marker design for low profile interventional cardiovascular MRI devices.

Engin Baysoy1,2, Dursun Korel Yildirim3, Cagla Ozsoy3, Senol Mutlu4, Ozgur Kocaturk3.   

Abstract

OBJECTIVES: A new microfabrication method to produce low profile radio frequency (RF) resonant markers on catheter shafts was developed. A semi-active RF resonant marker incorporating a solenoid and a plate capacitor was constructed on the distal shaft of a 5 Fr guiding catheter. The resulting device can be used for interventional cardiovascular MRI procedures.
MATERIALS AND METHODS: Unlike current semi-active device visualization techniques that require rigid and bulky analog circuit components (capacitor and solenoid), we fabricated a low profile RF resonant marker directly on guiding the catheter surface by thin film metal deposition and electroplating processes using a modified physical vapor deposition system.
RESULTS: The increase of the overall device profile thickness caused by the semi-active RF resonant marker (130 µm thick) was lowered by a factor of 4.6 compared with using the thinnest commercial non-magnetic and rigid circuit components (600 µm thick). Moreover, adequate visibility performance of the RF resonant marker in different orientations and overall RF safety were confirmed through in vitro experiments under MRI successfully.
CONCLUSION: The developed RF resonant marker on a clinical grade 5 Fr guiding catheter will enable several interventional congenital heart disease treatment procedures under MRI.

Entities:  

Keywords:  Interventional MRI; RF antenna; RF resonant marker; Thin film coating; iCMRI

Mesh:

Substances:

Year:  2016        PMID: 27605033     DOI: 10.1007/s10334-016-0586-8

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  23 in total

1.  Real-time MR Guidance for inferior vena cava filter placement in an animal model.

Authors:  A Bücker; J M Neuerburg; G B Adam; A Glowinski; T Schaeffter; V Rasche; J J van Vaals; R W Günther
Journal:  J Vasc Interv Radiol       Date:  2001-06       Impact factor: 3.464

2.  Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model.

Authors:  Simon Schalla; Maythem Saeed; Charles B Higgins; Oliver Weber; Alastair Martin; Phillip Moore
Journal:  J Magn Reson Imaging       Date:  2005-03       Impact factor: 4.813

3.  Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Ranil Desilva; Ronnier J Aviles; Victor J Wright; William H Schenke; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2006-04       Impact factor: 2.692

4.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

5.  Electronic characterization of lithographically patterned microcoils for high sensitivity NMR detection.

Authors:  Vasiliki Demas; Anthony Bernhardt; Vince Malba; Kristl L Adams; Lee Evans; Christopher Harvey; Robert S Maxwell; Julie L Herberg
Journal:  J Magn Reson       Date:  2009-06-09       Impact factor: 2.229

6.  Real-time MR-guided retrieval of inferior vena cava filters: an in vitro and animal model study.

Authors:  Ming-Chen Paul Shih; Walter J Rogers; Hugo Bonatti; Klaus D Hagspiel
Journal:  J Vasc Interv Radiol       Date:  2011-04-08       Impact factor: 3.464

7.  MR-guided placement of a temporary vena cava filter: technique and feasibility.

Authors:  C Frahm; H B Gehl; H Lorch; M Zwaan; M Drobnitzky; G A Laub; H D Weiss
Journal:  J Magn Reson Imaging       Date:  1998 Jan-Feb       Impact factor: 4.813

8.  Resonant marker design and fabrication techniques for device visualization during interventional magnetic resonance imaging.

Authors:  Mandy Kaiser; Markus Detert; Martin A Rube; Abubakr El-Tahir; Ole Jakob Elle; Andreas Melzer; Bertram Schmidt; Georg H Rose
Journal:  Biomed Tech (Berl)       Date:  2015-04       Impact factor: 1.411

9.  Designing passive MRI-safe implantable conducting leads with electrodes.

Authors:  Paul A Bottomley; Ananda Kumar; William A Edelstein; Justin M Allen; Parag V Karmarkar
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

10.  Noninvasive assessment of tissue heating during cardiac radiofrequency ablation using MRI thermography.

Authors:  Aravindan Kolandaivelu; Menekhem M Zviman; Valeria Castro; Albert C Lardo; Ronald D Berger; Henry R Halperin
Journal:  Circ Arrhythm Electrophysiol       Date:  2010-07-24
View more
  1 in total

1.  A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T.

Authors:  Dursun Korel Yildirim; Christopher Bruce; Dogangun Uzun; Toby Rogers; Kendall O'Brien; Rajiv Ramasawmy; Adrienne Campbell-Washburn; Daniel A Herzka; Robert J Lederman; Ozgur Kocaturk
Journal:  Magn Reson Med       Date:  2021-04-16       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.