Literature DB >> 11042634

Interventional MRA and intravascular imaging.

M E Ladd1, H H Quick, J F Debatin.   

Abstract

Several attributes make magnetic resonance imaging (MRI) attractive for guidance of intravascular therapeutic procedures, including high soft tissue contrast, imaging in arbitrary oblique planes, lack of ionizing radiation, and the ability to provide functional information, such as flow velocity or flow volume per unit time, in conjunction with morphologic information. For MR guidance of vascular interventions to be safe, the interventionalist must be able to visualize catheters and guidewires relative to the vascular system and surrounding tissues. A number of approaches for rendering instruments visible in an MR environment have been developed, including both passive and active techniques. Passive techniques depend on contrast agents or susceptibility artifacts that enhance the appearance of the catheter in the image itself, whereas active techniques rely on supplemental hardware built into the catheter, such as a radiofrequency (RF) coil. Additionally, the ability to introduce an RF coil mounted on a catheter presents the opportunity to obtain high-resolution images of the vessel wall. These images can provide the capability to distinguish and identify various plaque components. The additional capabilities of MRI could potentially open up new applications within the purview of vascular interventions beyond those currently performed under X-ray fluoroscopic guidance. Copyright 2000 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2000        PMID: 11042634     DOI: 10.1002/1522-2586(200010)12:4<534::aid-jmri4>3.0.co;2-q

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  A brief review of hardware for catheter tracking in magnetic resonance imaging.

Authors:  Jeffrey L Duerk; Eddy Y Wong; Jonathan S Lewin
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

2.  Real-time volume rendered MRI for interventional guidance.

Authors:  Michael A Guttman; Robert J Lederman; Jonathan M Sorger; Elliot R McVeigh
Journal:  J Cardiovasc Magn Reson       Date:  2002       Impact factor: 5.364

Review 3.  Magnetic resonance imaging of coronary atherosclerosis.

Authors:  Zahi A Fayad; Robin P Choudhury; Valentin Fuster
Journal:  Curr Atheroscler Rep       Date:  2003-09       Impact factor: 5.113

Review 4.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

5.  Prospective motion correction using tracking coils.

Authors:  Lei Qin; Ehud J Schmidt; Zion Tsz Ho Tse; Juan Santos; William S Hoge; Clare Tempany-Afdhal; Kim Butts-Pauly; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2012-05-07       Impact factor: 4.668

6.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

7.  MRI-guided prostate motion tracking by means of multislice-to-volume registration.

Authors:  Hadi Tadayyon; Siddharth Vikal; Sean Gill; Andras Lasso; Gabor Fichtinger
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010

8.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

Review 9.  Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Authors:  Fabio Settecase; Alastair J Martin; Prasheel Lillaney; Aaron Losey; Steven W Hetts
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

10.  Real-time magnetic resonance imaging - guided coronary intervention in a porcine model.

Authors:  Timo Heidt; Simon Reiss; Axel J Krafft; Ali Caglar Özen; Thomas Lottner; Christoph Hehrlein; Roland Galmbacher; Gian Kayser; Ingo Hilgendorf; Peter Stachon; Dennis Wolf; Andreas Zirlik; Klaus Düring; Manfred Zehender; Stephan Meckel; Dominik von Elverfeldt; Christoph Bode; Michael Bock; Constantin von Zur Mühlen
Journal:  Sci Rep       Date:  2019-06-17       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.