Literature DB >> 11039798

Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup.

F Prudhommeaux1, M Hamadouche, J Nevelos, C Doyle, A Meunier, L Sedel.   

Abstract

The surface topography of 11 alumina-on-alumina hip arthroplasties retrieved for aseptic loosening at a mean 11-year followup was investigated. Macroscopic wear was assessed using a coordinate measuring machine. Microscopic wear features were evaluated by Talysurf analysis. Scanning electron microscopy was used to look at the alumina microstructure. Components were classified into three groups: (1) low wear with no sign of wear and average arithmetic roughness values below 0.05 microm; (2) stripe wear with a visible oblong worn area on the femoral heads and penetration rates below 10 microm/year; and (3) severe wear with a visible loss of material on both components, showing total roughness values as much as 4 microm and maximum penetrations higher than 150 microm. Alumina quality assessed by grain size measurements and porosity percentages improved progressively from 1977 to 1988. This resulted in a correlated decrease of the microscopic wear magnitude. However, on a macroscopic scale, factors responsible for either a load increase (weight, young age, and male gender) or impairment in the load distribution over the component surfaces (large grain size, nonoptimal initial cup inclination, and cup migration and/or tilting) increased the penetration rates.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11039798     DOI: 10.1097/00003086-200010000-00014

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

2.  Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.

Authors:  Jaime A Carvajal Alba; Marcella E Elpers; Andrew E Rosenberg; Raymond P Robinson
Journal:  HSS J       Date:  2015-05-27

3.  Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?

Authors:  Rocco P Pitto; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  Clinical faceoff: Ceramic-on-ceramic THA: do the advantages outweigh the limitations?

Authors:  Laurent Sedel; William L Walter; Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2014-05-13       Impact factor: 4.176

Review 5.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

6.  Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?

Authors:  Rocco P Pitto; Mikaela Garland; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  Is there a risk in placing a ceramic head on a previously implanted trunion?

Authors:  Didier Hannouche; Jérôme Delambre; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

8.  Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?

Authors:  Henning R Johansson; Aaron J Johnson; Michael G Zywiel; Marybeth Naughton; Michael A Mont; Peter M Bonutti
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

9.  Vascularized fibular grafting for osteonecrosis of the femoral head with unusual indications.

Authors:  J Mack Aldridge; James R Urbaniak
Journal:  Clin Orthop Relat Res       Date:  2008-03-21       Impact factor: 4.176

10.  Retrieval analysis of alumina ceramic-on-ceramic bearing couples.

Authors:  Muhammad Korim; Susan Scholes; Anthony Unsworth; Richard Power
Journal:  Acta Orthop       Date:  2014-04       Impact factor: 3.717

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.