Literature DB >> 11028891

Methods for determining the accuracy of radiostereometric analysis (RSA).

L Ryd1, X Yuan, H Löfgren.   

Abstract

The problem of determining the noise level in any measuring system remains urgent. Radiostereometric analysis (RSA) is a radiographic system of unique accuracy which has applications in areas where minute motions or no motion at all occurs. Examples are micromotion between endoprostheses and bone and in fracture healing. We have determined the accuracy of the RSA system as applied to a clinical series of spinal fusions, where the conditions for RSA were not optimal. Using the usual test-retest methodology on a phantom, we showed that its accuracy can be grossly overestimated in the individual case. We found considerable variations in the accuracy in the individual case, depending on the rigid-body configuration. The overall accuracy, expressed as 3-D "vectors" for rotation and translation, respectively, correlated with the condition number, a method for characterizing the marker configuration. Indeed, the condition number explained as much as 92% of the variation in overall rotation. This condition number, however, cannot be used to analyze the accuracy of one degree of freedom of rotation alone. Mathematical simulation of the accuracy in the individual case of the individual dimension, using in-house software, showed that the accuracy (95% confidence) varied between 0.4 and 4.6 degrees of rotation about the transverse axis, corresponding to a clinical stress series of extension and flexion.

Entities:  

Mesh:

Year:  2000        PMID: 11028891     DOI: 10.1080/000164700317393420

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  21 in total

1.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

2.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

3.  Accuracy of model-based RSA contour reduction in a typical clinical application.

Authors:  Christof Hurschler; Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen
Journal:  Clin Orthop Relat Res       Date:  2008-05-29       Impact factor: 4.176

4.  Is Model-based Radiostereometric Analysis Suitable for Clinical Trials of a Cementless Tapered Wedge Femoral Stem?

Authors:  Sanaz Nazari-Farsani; Sami Finnilä; Niko Moritz; Kimmo Mattila; Jessica J Alm; Hannu T Aro
Journal:  Clin Orthop Relat Res       Date:  2016-06-22       Impact factor: 4.176

5.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

6.  Subsidence of callotasis zone in distraction osteogenesis after external fixator removal, measured by RSA.

Authors:  Ragnhild B Gunderson; Harald Steen; Joachim Horn; Leif Pål Kristiansen
Journal:  Acta Orthop       Date:  2010-11-11       Impact factor: 3.717

7.  Notes on the use and interpretation of radiostereometric analysis.

Authors:  Brian Derbyshire; Robin J Prescott; Martyn L Porter
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

8.  Clinical and radiological evaluation of Trabecular Metal and the Smith-Robinson technique in anterior cervical fusion for degenerative disease: a prospective, randomized, controlled study with 2-year follow-up.

Authors:  Håkan Löfgren; M Engquist; P Hoffmann; B Sigstedt; L Vavruch
Journal:  Eur Spine J       Date:  2009-09-18       Impact factor: 3.134

9.  Dependence of model-based RSA accuracy on higher and lower implant surface model quality.

Authors:  Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen; Christof Hurschler
Journal:  Biomed Eng Online       Date:  2013-04-16       Impact factor: 2.819

10.  Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses. A randomized clinical RSA study with 2-year follow-up.

Authors:  Torben Baek Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2013-01-23       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.