Literature DB >> 11025504

Turbo ASL: arterial spin labeling with higher SNR and temporal resolution.

E C Wong1, W M Luh, T T Liu.   

Abstract

A modified pulsed arterial spin labeling (ASL) technique is introduced here that has both higher temporal resolution and higher SNR per unit time than existing ASL techniques. In this technique, the time TI between the application of the tag and image acquisition is longer than the repetition time TR, allowing for the use of greatly reduced TR values without a significant decrease in the amplitude of the ASL signal. This improves both the temporal resolution and the sensitivity of ASL for functional brain mapping.

Mesh:

Substances:

Year:  2000        PMID: 11025504     DOI: 10.1002/1522-2594(200010)44:4<511::aid-mrm2>3.0.co;2-6

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  MR perfusion imaging by alternate slab width inversion recovery arterial spin labeling (AIRASL): a technique with higher signal-to-noise ratio at 3.0 T.

Authors:  Yasuhiro Fujiwara; Hirohiko Kimura; Tosiaki Miyati; Hiroyuki Kabasawa; Tsuyoshi Matsuda; Yoshiyuki Ishimori; Isao Yamaguchi; Toshiki Adachi
Journal:  MAGMA       Date:  2012-01-13       Impact factor: 2.310

2.  Estimation efficiency and statistical power in arterial spin labeling fMRI.

Authors:  Jeanette A Mumford; Luis Hernandez-Garcia; Gregory R Lee; Thomas E Nichols
Journal:  Neuroimage       Date:  2006-07-24       Impact factor: 6.556

3.  Continuous ASL perfusion fMRI investigation of higher cognition: quantification of tonic CBF changes during sustained attention and working memory tasks.

Authors:  Junghoon Kim; John Whyte; Jiongjiong Wang; Hengyi Rao; Kathy Z Tang; John A Detre
Journal:  Neuroimage       Date:  2006-01-19       Impact factor: 6.556

4.  Imaging mesial temporal lobe activation during scene encoding: comparison of fMRI using BOLD and arterial spin labeling.

Authors:  María A Fernández-Seara; Jiongjiong Wang; Ze Wang; Marc Korczykowski; Matthias Guenther; David A Feinberg; John A Detre
Journal:  Hum Brain Mapp       Date:  2007-12       Impact factor: 5.038

5.  Arterial spin labeling of cerebral perfusion territories using a separate labeling coil.

Authors:  Fernando F Paiva; Alberto Tannús; S Lalith Talagala; Afonso C Silva
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

6.  Increased SNR efficiency in velocity selective arterial spin labeling using multiple velocity selective saturation modules (mm-VSASL).

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2014-09-22       Impact factor: 4.668

7.  Underestimation of cerebral perfusion on flow-sensitive alternating inversion recovery image: semiquantitative evaluation with time-to-peak values.

Authors:  H S Kim; S Y Kim; J M Kim
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-26       Impact factor: 3.825

8.  Wedge-shaped slice-selective adiabatic inversion pulse for controlling temporal width of bolus in pulsed arterial spin labeling.

Authors:  Jia Guo; Richard B Buxton; Eric C Wong
Journal:  Magn Reson Med       Date:  2015-10-09       Impact factor: 4.668

9.  Resting cerebral blood flow: a potential biomarker of the effects of HIV in the brain.

Authors:  B M Ances; D Sisti; F Vaida; C L Liang; O Leontiev; J E Perthen; R B Buxton; D Benson; D M Smith; S J Little; D D Richman; D J Moore; R J Ellis
Journal:  Neurology       Date:  2009-09-01       Impact factor: 9.910

Review 10.  New acquisition techniques and their prospects for the achievable resolution of fMRI.

Authors:  Saskia Bollmann; Markus Barth
Journal:  Prog Neurobiol       Date:  2020-10-23       Impact factor: 11.685

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.