Literature DB >> 11023222

Reliability and running speed effects of in-shoe loading measurements during slow treadmill running.

T W Kernozek1, K A Zimmer.   

Abstract

In-shoe measurement systems allow the clinician and researcher to examine the loading parameters within the shoe. This study sought to investigate the test retest reliability and speed effects of in-shoe loading parameters using the Pedar System (Novel GMBH Munich) during slow treadmill running. The results indicated good to excellent test retest reliability between the two days test-Intraclass correlation coefficients (ICC's) ranged from 0.84-0.99 depending on the plantar region and variable analyzed. All plantar loading variables increased (peak pressure, peak pressure time impulse, peak force, and force time impulse) with the exception of contact area when treadmill running speed was increased from 2.24 m/s to 3.13 m/s. Results indicate that control of running speed is essential in obtaining reproducible data using this system to measure in-shoe loading data.

Mesh:

Year:  2000        PMID: 11023222     DOI: 10.1177/107110070002100906

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  13 in total

1.  Computational techniques for using insole pressure sensors to analyse three-dimensional joint kinetics.

Authors:  Elizabeth S Chumanov; C David Remy; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-10       Impact factor: 1.763

2.  Effects of the playing surface on plantar pressures and potential injuries in tennis.

Authors:  O Girard; F Eicher; F Fourchet; J P Micallef; G P Millet
Journal:  Br J Sports Med       Date:  2007-06-12       Impact factor: 13.800

3.  Repeated sprinting on natural grass impairs vertical stiffness but does not alter plantar loading in soccer players.

Authors:  Olivier Girard; Sébastien Racinais; Luke Kelly; Grégoire P Millet; Franck Brocherie
Journal:  Eur J Appl Physiol       Date:  2011-03-03       Impact factor: 3.078

4.  Is Plantar Loading Altered During Repeated Sprints on Artificial Turf in International Football Players?

Authors:  Olivier Girard; Grégoire P Millet; Athol Thomson; Franck Brocherie
Journal:  J Sports Sci Med       Date:  2018-08-14       Impact factor: 2.988

5.  The accuracy of an automasking algorithm in plantar pressure measurements.

Authors:  Scott J Ellis; Hill Stoecklein; Joseph C Yu; Grisha Syrkin; Howard Hillstrom; Jonathan T Deland
Journal:  HSS J       Date:  2010-11-30

6.  Reliability of the TekScan MatScan(R) system for the measurement of plantar forces and pressures during barefoot level walking in healthy adults.

Authors:  Gerard V Zammit; Hylton B Menz; Shannon E Munteanu
Journal:  J Foot Ankle Res       Date:  2010-06-18       Impact factor: 2.303

7.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

8.  The effect of foot orthoses with forefoot cushioning or metatarsal pad on forefoot peak plantar pressure in running.

Authors:  Michaela Hähni; Anja Hirschmüller; Heiner Baur
Journal:  J Foot Ankle Res       Date:  2016-11-16       Impact factor: 2.303

Review 9.  Technologies for Advanced Gait and Balance Assessments in People with Multiple Sclerosis.

Authors:  Camille J Shanahan; Frederique M C Boonstra; L Eduardo Cofré Lizama; Myrte Strik; Bradford A Moffat; Fary Khan; Trevor J Kilpatrick; Anneke van der Walt; Mary P Galea; Scott C Kolbe
Journal:  Front Neurol       Date:  2018-02-02       Impact factor: 4.003

10.  Plantar Pressure Variability and Asymmetry in Elderly Performing 60-Minute Treadmill Brisk-Walking: Paving the Way towards Fatigue-Induced Instability Assessment Using Wearable In-Shoe Pressure Sensors.

Authors:  Guoxin Zhang; Duo Wai-Chi Wong; Ivy Kwan-Kei Wong; Tony Lin-Wei Chen; Tommy Tung-Ho Hong; Yinghu Peng; Yan Wang; Qitao Tan; Ming Zhang
Journal:  Sensors (Basel)       Date:  2021-05-06       Impact factor: 3.576

View more