Literature DB >> 11021693

Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET.

A Chatziioannou1, J Qi, A Moore, A Annala, K Nguyen, R Leahy, S R Cherry.   

Abstract

We have evaluated the performance of two three-dimensional (3-D) reconstruction algorithms with data acquired from microPET, a high resolution tomograph dedicated to small animal imaging. The first was a linear filtered-backprojection algorithm (FBP) with reprojection of the missing data, and the second was a statistical maximum a posteriori probability algorithm (MAP). The two algorithms were evaluated in terms of their resolution performance, both in phantoms and in vivo. Sixty independent realizations of a phantom simulating the brain of a baby monkey were acquired, each containing three million counts. Each of these realizations was reconstructed independently with both algorithms. The ensemble of the 60 reconstructed realizations was used to estimate the standard deviation as a measure of the noise for each reconstruction algorithm. More detail was recovered in the MAP reconstruction without an increase in noise relative to FBP. Studies in a simple cylindrical compartment phantom demonstrated improved recovery of known activity ratios with MAP. Finally, in vivo studies also demonstrated a clear improvement in spatial resolution using the MAP algorithm. The quantitative accuracy of the MAP reconstruction was also evaluated by comparison with autoradiography and direct well counting of tissue samples and was shown to be superior.

Mesh:

Year:  2000        PMID: 11021693     DOI: 10.1109/42.870260

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  30 in total

Review 1.  PET imaging in small animals.

Authors:  Heinrich R Schelbert; Masayuki Inubushi; Robert S Ross
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

2.  Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method.

Authors:  Qinan Bao; Arion F Chatziioannou
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

Review 3.  Emerging imaging techniques.

Authors:  Elliot R McVeigh
Journal:  Circ Res       Date:  2006-04-14       Impact factor: 17.367

Review 4.  Preclinical imaging of mammary intraepithelial neoplasia with positron emission tomography.

Authors:  Craig K Abbey; Alexander D Borowsky; Jeffery P Gregg; Robert D Cardiff; Simon R Cherry
Journal:  J Mammary Gland Biol Neoplasia       Date:  2006-04       Impact factor: 2.673

5.  Cyclosporine, a P-glycoprotein modulator, increases [18F]MPPF uptake in rat brain and peripheral tissues: microPET and ex vivo studies.

Authors:  Goran Laćan; Alain Plenevaux; Daniel J Rubins; Baldwin M Way; Caroline Defraiteur; Christian Lemaire; Joel Aerts; André Luxen; Simon R Cherry; William P Melega
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-05       Impact factor: 9.236

6.  Positron-emission tomography reporter gene expression imaging in rat myocardium.

Authors:  Masayuki Inubushi; Joseph C Wu; Sanjiv S Gambhir; Gobalakrishnan Sundaresan; Nagichettiar Satyamurthy; Mohammad Namavari; Simon Yee; Jorge R Barrio; David Stout; Arion F Chatziioannou; Lily Wu; Heinrich R Schelbert
Journal:  Circulation       Date:  2003-01-21       Impact factor: 29.690

7.  Nitrogen-13 ammonia cardiac positron emission tomography in mice: effects of clonidine-induced changes in cardiac work on myocardial perfusion.

Authors:  Masayuki Inubushi; Maria C Jordan; Kenneth P Roos; Robert S Ross; Arion F Chatziioannou; David B Stout; Magnus Dahlbom; Heinrich R Schelbert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-10       Impact factor: 9.236

8.  Characterization of osteolytic, osteoblastic, and mixed lesions in a prostate cancer mouse model using 18F-FDG and 18F-fluoride PET/CT.

Authors:  Wellington K Hsu; Mandeep S Virk; Brian T Feeley; David B Stout; Arion F Chatziioannou; Jay R Lieberman
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

9.  In vivo positron-emission tomography imaging of progression and transformation in a mouse model of mammary neoplasia.

Authors:  Craig K Abbey; Alexander D Borowsky; Erik T McGoldrick; Jeffrey P Gregg; Jeannie E Maglione; Robert D Cardiff; Simon R Cherry
Journal:  Proc Natl Acad Sci U S A       Date:  2004-07-26       Impact factor: 11.205

10.  Dose, timing, schedule, and the choice of targeted epitope alter the efficacy of anti-CD22 immunotherapy in mice bearing human lymphoma xenografts.

Authors:  Robert T O'Donnell; Yunpeng Ma; Hayes C McKnight; David Pearson; Joseph M Tuscano
Journal:  Cancer Immunol Immunother       Date:  2009-05-13       Impact factor: 6.968

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.