Literature DB >> 11021688

Reconstruction of attenuation map using discrete consistency conditions.

A V Bronnikov1.   

Abstract

Methods of quantitative emission computed tomography require compensation for linear photon attenuation. A current trend in single-photon emission computed tomography (SPECT) and positron emission tomography (PET) is to employ transmission scanning to reconstruct the attenuation map. Such an approach, however, considerably complicates both the scanner design and the data acquisition protocol. A dramatic simplification could be made if the attenuation map could be obtained directly from the emission projections, without the use of a transmission scan. This can be done by applying the consistency conditions that enable us to identify the operator of the problem and, thus, to reconstruct the attenuation map. In this paper, we propose a new approach based on the discrete consistency conditions. One of the main advantages of the suggested method over previously used continuous conditions is that it can easily be applied in various scanning configurations, including fully three-dimensional (3-D) data acquisition protocols. Also, it provides a stable numerical implementation, allowing us to avoid the crosstalk between the attenuation map and the source function. A computationally efficient algorithm is implemented by using the QR and Cholesky decompositions. Application of the algorithm to computer-generated and experimentally measured SPECT data is considered.

Mesh:

Year:  2000        PMID: 11021688     DOI: 10.1109/42.870255

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Attenuation correction in SPECT without attenuation map.

Authors:  Krzysztof Kacperski
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011

3.  Attenuation map estimation with SPECT emission data only.

Authors:  Yan Yan; Gengsheng Lawrence Zeng
Journal:  Int J Imaging Syst Technol       Date:  2009-09-01       Impact factor: 2.000

4.  Joint estimation of activity image and attenuation sinogram using time-of-flight positron emission tomography data consistency condition filtering.

Authors:  Quanzheng Li; Hao Li; Kyungsang Kim; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2017-04-26

5.  Deep-learning-based methods of attenuation correction for SPECT and PET.

Authors:  Xiongchao Chen; Chi Liu
Journal:  J Nucl Cardiol       Date:  2022-06-09       Impact factor: 5.952

6.  Anomaly Detection and Artifact Recovery in PET Attenuation-Correction Images Using the Likelihood Function.

Authors:  Charles M Laymon; James E Bowsher
Journal:  IEEE J Sel Top Signal Process       Date:  2013-02       Impact factor: 6.856

7.  Zero-Extra-Dose PET Delayed Imaging with Data-Driven Attenuation Correction Estimation.

Authors:  Lifang Pang; Wentao Zhu; Yun Dong; Yang Lv; Hongcheng Shi
Journal:  Mol Imaging Biol       Date:  2019-02       Impact factor: 3.488

Review 8.  PET/MRI attenuation estimation in the lung: A review of past, present, and potential techniques.

Authors:  Joseph Lillington; Ludovica Brusaferri; Kerstin Kläser; Karin Shmueli; Radhouene Neji; Brian F Hutton; Francesco Fraioli; Simon Arridge; Manuel Jorge Cardoso; Sebastien Ourselin; Kris Thielemans; David Atkinson
Journal:  Med Phys       Date:  2020-01-01       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.