Literature DB >> 11011744

GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method.

S M Marcu1, Q J Wu, K Pillai, M S Weinhous.   

Abstract

This work provides a method for an independent check of Gamma Knife GammaPlan radiosurgery calculations, named the spherical approximation method or SAM. Based on skull dimension measurements, the treated volume of the head is modeled as a sphere of radius R. With this approximation, an analytical solution for fast ray tracing of the path length, for each of the 201 beamlets, of the Gamma Knife helmet collimator was possible. The dose rate at the focus of a single shot is the sum of the contributions of all active beamlets adjusted for both the collimator factor and attenuation. For an arbitrary point, the dose rate is derived at the beamlet level from the focus values adjusted for the new path length attenuation and the appropriate collimators' off-axis profiles. The sum over all beamlets' contributions gives the dose rate at that particular point. At the single shot level, SAM independent check results agree with the GammaPlan for patient calculations to better than +/-6% and, as expected, in spherical phantoms the agreements improve to better than +/-1.0%. For an arbitrary point, multi-shot procedure, the agreement is better than +/-3% and +/-1.5, respectively.

Entities:  

Mesh:

Year:  2000        PMID: 11011744     DOI: 10.1118/1.1287051

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  The variable ellipsoid modeling technique as a verification method for the treatment planning system of gamma knife radiosurgery.

Authors:  Beong Ik Hur; Byung Kwan Choi; Soon Ki Sung; Won Ho Cho; Seung Heon Cha; Chang Hwa Choi
Journal:  J Korean Neurosurg Soc       Date:  2010-02-28

2.  Independent dose verification for brain stereotactic radiotherapy using different add-on micro multi-leaf collimators.

Authors:  Shiro Nishiyama; Satoru Ishibashi; Ryo Takahashi; Hidenobu Tachibana
Journal:  Radiol Phys Technol       Date:  2017-04-19

3.  Effect of skull contours on dose calculations in Gamma Knife Perfexion stereotactic radiosurgery.

Authors:  Hisato Nakazawa; Masataka Komori; Yoshimasa Mori; Masahiro Hagiwara; Yuta Shibamoto; Takahiko Tsugawa; Chisa Hashizume; Tatsuya Kobayashi
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

4.  Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique.

Authors:  Beong Ik Hur; Seong Jin Jin; Gyeong Rip Kim; Jong Hyeok Kwak; Young Ha Kim; Sang Weon Lee; Soon Ki Sung
Journal:  J Korean Neurosurg Soc       Date:  2021-01-01

5.  Clinical application of gamma knife dose verification method in multiple brain tumors : modified variable ellipsoid modeling technique.

Authors:  Beong Ik Hur; Jae Min Lee; Won Ho Cho; Dong Wan Kang; Choong Rak Kim; Byung Kwan Choi
Journal:  J Korean Neurosurg Soc       Date:  2013-02-28

6.  Two-year experience with the commercial Gamma Knife Check software.

Authors:  Andy Yuanguang Xu; Jagdish Bhatnagar; Greg Bednarz; Josef Novotny; John Flickinger; L Dade Lunsford; M Saiful Huq
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

7.  Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.

Authors:  Stewart J Becker; Ying Niu; Yildirim Mutaf; Shifeng Chen; Yannick Poirier; Elizabeth M Nichols; ByongYong Yi
Journal:  J Appl Clin Med Phys       Date:  2019-12       Impact factor: 2.102