Literature DB >> 11007522

Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms.

T Smith1, N Petoussi-Henss, M Zankl.   

Abstract

The aim of this study was to use a new system of realistic voxel phantoms, based on computed tomography scanning of humans, to assess its ability to specify the internal dosimetry of selected human examples in comparison with the well-established MIRD system of mathematical anthropomorphic phantoms. Differences in specific absorbed fractions between the two systems were inferred by using organ dose estimates as the end point for comparison. A "family" of voxel phantoms, comprising an 8-week-old baby, a 7-year-old child and a 38-year-old adult, was used and a close match to these was made by interpolating between organ doses estimated for pairs of the series of six MIRD phantoms. Using both systems, doses were calculated for up to 22 organs for four radiopharmaceuticals with widely differing biodistribution and emission characteristics (technetium-99m pertechnetate, administered without thyroid blocking; iodine-123 iodide; indium-111 antimyosin; oxygen-15 water). Organ dose estimates under the MIRD system were derived using the software MIRDOSE 3, which incorporates specific absorbed fraction (SAF) values for the MIRD phantom series. The voxel system uses software based on the same dose calculation formula in conjunction with SAF values determined by Monte Carlo analysis at the GSF of the three voxel phantoms. Effective doses were also compared. Substantial differences in organ weights were observed between the two systems, 18% differing by more than a factor of 2. Out of a total of 238 organ dose comparisons, 5% differed by more than a factor of 2 between the systems; these included some doses to walls of the GI tract, a significant result in relation to their high tissue weighting factors. Some of the largest differences in dose were associated with organs of lower significance in terms of radiosensitivity (e.g. thymus). In this small series, voxel organ doses tended to exceed MIRD values, on average, and a 10% difference was significant when all 238 organ doses were considered as a single group. In 12 comparisons of effective dose, the mean voxel to MIRD ratio was 1.07 (range 0.72-1.32). It was shown for the majority of cases that, whereas some large differences in SAF values exist, differences in source organ and effective dose values between the MIRD and voxel methods were largely accounted for by the respective organ mass differences. The reasons for various organ dose differences with the selected radiopharmaceuticals are discussed. Taking biological variation into account, there is reasonable agreement between the two methods but some significant differences exist that warrant further investigation. More extensive comparisons involving a wide variety of voxel phantoms are required to establish whether realistic voxel phantoms should eventually replace the MIRD system.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11007522     DOI: 10.1007/s002590000294

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  PAVA: physiological and anatomical visual analytics for mapping of tissue-specific concentration and time-course data.

Authors:  Michael-Rock Goldsmith; Thomas R Transue; Daniel T Chang; Rogelio Tornero-Velez; Michael S Breen; Curtis C Dary
Journal:  J Pharmacokinet Pharmacodyn       Date:  2010-05-22       Impact factor: 2.745

2.  Specific absorbed fractions for internal electron emitters derived for a set of anatomically realistic reference pregnant female models.

Authors:  Bingqi Guo; X George Xu; Chengyu Shi
Journal:  Radiat Prot Dosimetry       Date:  2009-09-18       Impact factor: 0.972

3.  Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code.

Authors:  Ali Asghar Parach; Hossein Rajabi; Mohammad Ali Askari
Journal:  Radiat Environ Biophys       Date:  2011-05-15       Impact factor: 1.925

4.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

Review 5.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

6.  Development of a new Python-based cardiac phantom for myocardial SPECT imaging.

Authors:  Osama S Hanafy; Magdy M Khalil; Ibrahim M Khater; Haitham S Mohammed
Journal:  Ann Nucl Med       Date:  2020-10-17       Impact factor: 2.668

7.  Internal photon and electron dosimetry of the newborn patient--a hybrid computational phantom study.

Authors:  Michael Wayson; Choonsik Lee; George Sgouros; S Ted Treves; Eric Frey; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

8.  Radiopharmaceutical Formulation and Preclinical Testing of 68Ga-Labeled DOTA-MGS5 for the Regulatory Approval of a First Exploratory Clinical Trial.

Authors:  Anton A Hörmann; Maximilian Klingler; Christine Rangger; Christian Mair; Clemens Decristoforo; Christian Uprimny; Irene J Virgolini; Elisabeth von Guggenberg
Journal:  Pharmaceuticals (Basel)       Date:  2021-06-16
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.