Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code.

Ali Asghar Parach1, Hossein Rajabi, Mohammad Ali Askari.   

Abstract

GATE/GEANT is a Monte Carlo code dedicated to nuclear medicine that allows calculation of the dose to organs of voxel phantoms. On the other hand, MIRD is a well-developed system for estimation of the dose to human organs. In this study, results obtained from GATE/GEANT using Snyder phantom are compared to published MIRD data. For this, the mathematical Snyder phantom was discretized and converted to a digital phantom of 100 × 200 × 360 voxels. The activity was considered uniformly distributed within kidneys, liver, lungs, pancreas, spleen, and adrenals. The GATE/GEANT Monte Carlo code was used to calculate the dose to the organs of the phantom from mono-energetic photons of 10, 15, 20, 30, 50, 100, 200, 500, and 1000 keV. The dose was converted into specific absorbed fraction (SAF) and the results were compared to the corresponding published MIRD data. On average, there was a good correlation (r (2)>0.99) between the two series of data. However, the GATE/GEANT data were on average -0.16 ± 6.22% lower than the corresponding MIRD data for self-absorption. Self-absorption in the lungs was considerably higher in the MIRD compared to the GATE/GEANT data, for photon energies of 10-20 keV. As for cross-irradiation to other organs, the GATE/GEANT data were on average +1.5 ± 8.1% higher than the MIRD data, for photon energies of 50-1000 keV. For photon energies of 10-30 keV, the relative difference was +7.5 ± 67%. It turned out that the agreement between the GATE/GEANT and the MIRD data depended upon absolute SAF values and photon energy. For 10-30 keV photons, where the absolute SAF values were small, the uncertainty was high and the effect of cross-section prominent, and there was no agreement between the GATE/GEANT results and the MIRD data. However, for photons of 50-1,000 keV, the bias was negligible and the agreement was acceptable.

Entities:  

Mesh:

Year:  2011        PMID: 21573984     DOI: 10.1007/s00411-011-0370-0

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  36 in total

Review 1.  Developments in the internal dosimetry of radiopharmaceuticals.

Authors:  M G Stabin
Journal:  Radiat Prot Dosimetry       Date:  2003       Impact factor: 0.972

2.  Application of the ICRP/ICRU reference computational phantoms to internal dosimetry: calculation of specific absorbed fractions of energy for photons and electrons.

Authors:  L Hadid; A Desbrée; H Schlattl; D Franck; E Blanchardon; M Zankl
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

Review 3.  Dosimetry of internal emitters.

Authors:  George Sgouros
Journal:  J Nucl Med       Date:  2005-01       Impact factor: 10.057

4.  OEDIPE: a personalized dosimetric tool associating voxel-based models with MCNPX.

Authors:  Sophie Chiavassa; Manuel Bardiès; Françoise Guiraud-Vitaux; Damien Bruel; Jean-Rene Jourdain; Didier Franck; Isabelle Aubineau-Lanièce
Journal:  Cancer Biother Radiopharm       Date:  2005-06       Impact factor: 3.099

5.  Implementing dosimetry in GATE: dose-point kernel validation with GEANT4 4.8.1.

Authors:  Ludovic Ferrer; Nicolas Chouin; Abdalkader Bitar; Albert Lisbona; Manuel Bardiès
Journal:  Cancer Biother Radiopharm       Date:  2007-02       Impact factor: 3.099

6.  OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.

Authors:  Michael G Stabin; Richard B Sparks; Eric Crowe
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

7.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

Review 8.  Update: the case for patient-specific dosimetry in radionuclide therapy.

Authors:  Michael G Stabin
Journal:  Cancer Biother Radiopharm       Date:  2008-06       Impact factor: 3.099

9.  Validation of a dose deposited by low-energy photons using GATE/GEANT4.

Authors:  C O Thiam; V Breton; D Donnarieix; B Habib; L Maigne
Journal:  Phys Med Biol       Date:  2008-05-19       Impact factor: 3.609

10.  Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

View more
  4 in total

1.  A review of 3D image-based dosimetry, technical considerations and emerging perspectives in 90Y microsphere therapy.

Authors:  Jim O' Doherty
Journal:  J Diagn Imaging Ther       Date:  2015-04-28

Review 2.  Preclinical Voxel-Based Dosimetry in Theranostics: a Review.

Authors:  Arun Gupta; Min Sun Lee; Joong Hyun Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-04-19

3.  Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPATc-DTPA Radiopharmaceutical using MIRDOSE Software.

Authors:  Ebrahimnejad Gorji K; Abedi Firouzjah R; Khanzadeh F; Abdi-Goushbolagh N; Banaei A; Ataei Gh
Journal:  J Biomed Phys Eng       Date:  2019-06-01

4.  A 3D Monte Carlo Method for Estimation of Patient-specific Internal Organs Absorbed Dose for (99m)Tc-hynic-Tyr(3)-octreotide Imaging.

Authors:  Mehdi Momennezhad; Shahrokh Nasseri; Seyed Rasoul Zakavi; Ali Asghar Parach; Mahdi Ghorbani; Ruhollah Ghahraman Asl
Journal:  World J Nucl Med       Date:  2016 May-Aug
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.