Literature DB >> 11006383

Digital automated RSA compared to manually operated RSA.

E R Valstar1, H A Vrooman, S Toksvig-Larsen, L Ryd, R G Nelissen.   

Abstract

The accuracy of digital Roentgen stereophotogrammetric analysis (RSA) was compared to the accuracy of a manually operated RSA system. For this purpose, we used radiographs of a phantom and radiographs of patients. The radiographs of the patients consisted of double examinations of 12 patients that had a tibial osteotomy and of double examinations of 12 patients that received a total hip prosthesis. First, the radiographs were measured manually with an accurate measurement table. Subsequently, the images were digitized by a film scanner at 150 DPI and 300 DPI resolutions and analyzed with the RSA-CMS software. In the phantom experiment, the manually operated system produced significantly better results than the digital system, although the maximum difference between the median values of the manually operated system and the digital system was as low as 0.013mm for translations and 0.033 degrees for rotations. In the radiographs of the patients, the manually operated system and the digital system produced equally accurate results: no significant differences in translations and rotations were found. We conclude that digital RSA is an accurate, fast, and user friendly alternative for manually operated RSA. Currently, digital RSA systems are being used in a growing number of clinical RSA-studies.

Entities:  

Mesh:

Year:  2000        PMID: 11006383     DOI: 10.1016/s0021-9290(00)00138-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  Effect of marker cluster design on the accuracy of human movement analysis using stereophotogrammetry.

Authors:  A Page; H De Rosario; V Mata; J V Hoyos; R Porcar
Journal:  Med Biol Eng Comput       Date:  2006-11-10       Impact factor: 2.602

2.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

Authors:  Chi-Pin Hsu; Shang-Chih Lin; Kao-Shang Shih; Chang-Hung Huang; Chian-Her Lee
Journal:  Med Biol Eng Comput       Date:  2014-10-08       Impact factor: 2.602

4.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

5.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

6.  Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

Authors:  Cyrus Brodén; Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Olof Sköldenberg
Journal:  Biomed Res Int       Date:  2016-07-10       Impact factor: 3.411

Review 7.  RSA in Spine: A Review.

Authors:  Ali Humadi; Sulaf Dawood; Klas Halldin; Brian Freeman
Journal:  Global Spine J       Date:  2017-07-28

8.  Dependence of model-based RSA accuracy on higher and lower implant surface model quality.

Authors:  Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen; Christof Hurschler
Journal:  Biomed Eng Online       Date:  2013-04-16       Impact factor: 2.819

9.  RSA-tested TKA Implants on Average Have Lower Mean 10-year Revision Rates Than Non-RSA-tested Designs.

Authors:  Shaho Hasan; Perla J Marang-van de Mheen; Bart L Kaptein; Rob G H H Nelissen; Bart G Pijls
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

10.  Measurement of the migration of a focal knee resurfacing implant with radiostereometry.

Authors:  Olof Sköldenberg; Thomas Eisler; André Stark; Olle Muren; Nicolas Martinez-Carranza; Leif Ryd
Journal:  Acta Orthop       Date:  2013-11-29       Impact factor: 3.717

View more