Literature DB >> 11005521

The effect of femoral component head size on posterior dislocation of the artificial hip joint.

R L Bartz1, P C Nobel, N R Kadakia, H S Tullos.   

Abstract

BACKGROUND: Posterior dislocation continues to be a relatively common complication following total hip arthroplasty. In addition to technical and patient-associated factors, prosthetic features have also been shown to influence stability of the artificial hip joint. In this study, a dynamic model of the artificial hip joint was used to examine the influence of the size of the head of the femoral component on the range of motion prior to impingement and posterior dislocation following total hip replacement.
METHODS: Six fresh cadaveric specimens were dissected, and an uncemented total hip prosthesis was implanted in each. Each specimen was mounted in a mechanical testing machine and loaded with use of a system of seven cables attached to the femur and pelvis that simulated the action of the major muscle groups crossing the hip joint. The hip was taken through a range of motion similar to that experienced when rising from a seated position. The three-dimensional position of the femur at the points of impingement and dislocation was recorded electronically. The range of joint motion was tested with prosthetic femoral heads of four different diameters (twenty-two, twenty-six, twenty-eight, and thirty-two millimeters).
RESULTS: Significant associations were noted between the femoral head size and the degree of flexion at dislocation in ten (p = 0.001), twenty (p < 0.001), and thirty (p = 0.003) degrees of adduction. Increasing the femoral head size from twenty-two to twenty-eight millimeters increased the range of flexion by an average of 5.6 degrees prior to impingement and by an average of 7.6 degrees prior to posterior dislocation; however, increasing the head size from twenty-eight to thirty-two millimeters did not lead to more significant improvement in the range of joint motion. The site of impingement prior to dislocation varied with the size of the femoral head. With a twenty-two-millimeter head, impingement occurred between the neck of the femoral prosthesis and the acetabular liner, whereas with a thirty-two-millimeter head, impingement most frequently occurred between the osseous femur and the pelvis.
CONCLUSIONS: With the particular prosthesis that was tested, increasing the diameter of the femoral head component increased the range of motion prior to impingement and dislocation, decreased the prevalence of prosthetic impingement, and increased the prevalence of osseous impingement. CLINICAL RELEVANCE: These results suggest that femoral heads with a twenty-eight-millimeter diameter increase the range of motion after total hip replacement. This may be beneficial when additional factors compromising joint stability are encountered.

Entities:  

Mesh:

Year:  2000        PMID: 11005521     DOI: 10.2106/00004623-200009000-00010

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  42 in total

1.  Implementing capsule representation in a total hip dislocation finite element model.

Authors:  Kristofer J Stewart; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2004

2.  The Frank Stinchfield Award: Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial?

Authors:  Donald S Garbuz; Bassam A Masri; Clive P Duncan; Nelson V Greidanus; Eric R Bohm; Martin J Petrak; Craig J Della Valle; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

Authors:  Adolph V Lombardi; Michael D Skeels; Keith R Berend; Joanne B Adams; Orlando J Franchi
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Computer-assisted versus manual alignment in THA: a probabilistic approach to range of motion.

Authors:  Anthony J Petrella; Joshua Q Stowe; Darryl D D'Lima; Paul J Rullkoetter; Peter J Laz
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

5.  [Diagnostics and therapy of luxation after total hip arthroplasty].

Authors:  B Preininger; F Haschke; C Perka
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

6.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

7.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

8.  Early dislocation rate in ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Mary E Hardwick; Richard H Walker; Steven N Copp; Kace A Ezzet; Clifford W Colwell
Journal:  HSS J       Date:  2008-02

9.  Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?

Authors:  Gianluca Cinotti; Niccolò Lucioli; Andrea Malagoli; Carlo Calderoli; Ferdinando Cassese
Journal:  Int Orthop       Date:  2010-02-17       Impact factor: 3.075

10.  Morbid obesity may increase dislocation in total hip patients: a biomechanical analysis.

Authors:  Jacob M Elkins; Matej Daniel; Douglas R Pedersen; Bhupinder Singh; H John Yack; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2012-08-21       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.