Literature DB >> 11003419

Dosimetric considerations in mammography.

K A Hatziioannou1, K Psarrakos, E Molyvda-Athanasopoulou, G Kitis, E Papanastassiou, I Sofroniadis, O Kimoundri.   

Abstract

The aim of this study was to measure the absorbed dose to seven organs other than the breast in mammography in order to calculate their contribution to the effective dose. The absorbed dose to these organs was measured using a lucite upper body anthropomorphic phantom containing thermoluminescent dosimeters (TLD) at appropriate locations, exposed as in a mammographic examination. In addition, the dependence of the absorbed dose on kVp, mAs and breast thickness was examined. The absorbed dose due to scattered radiation was found to be negligible to all organs except to the sternum red bone marrow (SRBM) and the thyroid. The mean doses to the SRBM and the thyroid, for a set of four exposures, one craniocaudal and one 90 degrees mediolateral per breast, simulating a complete breast screening examination, varied between 0.40 and 1.27 and 0.05-0.17 microGy mAs(-1), respectively, depending on the breast thickness and the kVp selection. Effective dose from mammography was also calculated based on the absorbed dose to the breast, the SRBM and the thyroid and tissue-weighting factors. The effective dose was found to vary between 0.66 and 0.85 microSv mAs(-1) depending on the breast thickness and the kVp value selected. The radiation dose to the breast contributes over 98% to the effective dose.

Entities:  

Mesh:

Year:  2000        PMID: 11003419     DOI: 10.1007/s003309900209

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  4 in total

1.  Radiation dose to organs and tissues from mammography: Monte Carlo and phantom study.

Authors:  Ioannis Sechopoulos; Sankararaman Suryanarayanan; Srinivasan Vedantham; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2007-12-04       Impact factor: 11.105

2.  Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.

Authors:  Ioannis Sechopoulos; Srinivasan Vedantham; Sankararaman Suryanarayanan; Carl J D'Orsi; Andrew Karellas
Journal:  Radiology       Date:  2008-02-21       Impact factor: 11.105

Review 3.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  Radiation dose affected by mammographic composition and breast size: first application of a radiation dose management system for full-field digital mammography in Korean women.

Authors:  Ji Eun Baek; Bong Joo Kang; Sung Hun Kim; Hyun Sil Lee
Journal:  World J Surg Oncol       Date:  2017-02-02       Impact factor: 2.754

  4 in total