Literature DB >> 10982663

Anatomic variations should be considered in total knee arthroplasty.

R Nagamine1, H Miura, C V Bravo, K Urabe, S Matsuda, K Miyanishi, G Hirata, Y Iwamoto.   

Abstract

The effect of anatomic variations on the operative techniques used in total knee arthroplasty (TKA) was assessed. In 133 Japanese patients with medial osteoarthritis (OA), six parameters were measured on anteroposterior radiographs of the lower extremities taken with the patients in the supine position. The results showed that the characteristics of the knees were bowing of the femoral shaft and proximal tibia vara, with lateral offset of the tibial shaft with respect to the center of the tibial plateau. The angle between a perpendicular to the mechanical axis and the tangent to the distal femoral condyles can be used in determining the external rotation of the femoral component. This angle was more than 3 degrees in 20% of the patients. The femoral component should therefore be externally rotated more than 3 degrees relative to the posterior condylar line in such patients. Because the center of the tibial plateau is located medial to the central line of the tibial shaft in knees with medial OA, the central point of the tibial articular surface should not be used for alignment of the tibial component. The medial offset stem of the tibial component may impinge against the medial wall. Anatomic variations should be evaluated before TKA is attempted.

Entities:  

Mesh:

Year:  2000        PMID: 10982663     DOI: 10.1007/s007760050157

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  51 in total

1.  Intraoperative assessment of resected condyle thickness in total knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Chul Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-24       Impact factor: 4.342

2.  Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA.

Authors:  Eun-Kyoo Song; Jong-Keun Seon; Ji-Hyeon Yim; Nathan A Netravali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  Stem length in revision total knee arthroplasty.

Authors:  Anay Rajendra Patel; Brian Barlow; Amar S Ranawat
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

4.  Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity.

Authors:  Dhanasekararaja Palanisami; Geethan Iyyampillai; Sivaraj Shanmugam; Rajkumar Natesan; Rajasekaran S
Journal:  Int Orthop       Date:  2016-02-05       Impact factor: 3.075

5.  Computerized tomography scout view for determining distal femoral resection angle in intramedullary instrumentation of total knee arthroplasty.

Authors:  M Murad Uslu; Baris Ozsar; Meric Cirpar; Simay Kara; Fatih Eksioglu; Ozgur Cetik
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-22       Impact factor: 4.342

6.  Total knee arthroplasty following closed wedge high tibial osteotomy.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon
Journal:  Int Orthop       Date:  2009-04-15       Impact factor: 3.075

7.  Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.

Authors:  Tsan-Wen Huang; Kuo-Ti Peng; Kuo-Chin Huang; Mel S Lee; Robert Wen-Wei Hsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-21       Impact factor: 4.342

8.  Slight under-correction using individualized intentional varus femoral cutting leads to favorable outcomes in patients with lateral femoral bowing and varus knee.

Authors:  Han-Jun Lee; Jung-Won Lim; Dong-Hoon Lee; Dong-Hyun Kim; Yong-Beom Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-22       Impact factor: 4.342

9.  Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system.

Authors:  Ming Han Lincoln Liow; Pak Lin Chin; Keng Jin Darren Tay; Shi Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Singapore Med J       Date:  2014-10       Impact factor: 1.858

10.  Accuracy of image-free navigation for severely deformed knees.

Authors:  Minoru Takasaki; Shuichi Matsuda; Shingo Fukagawa; Hiroaki Mitsuyasu; Hiromasa Miura; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-17       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.