Effect of hip prostheses on radiotherapy dose.

M Carolan1, P Dao, C Fox, P Metcalfe.   

Abstract

A small but growing proportion of patients requiring radiotherapy for prostate cancer have one or two hip prostheses which may shadow the target and affect the dose distribution. Approximately 10 such patients are treated at the Illawarra Cancer Care Centre per year. Hence a study was undertaken to examine the accuracy of various treatment methods that involve some of the treatment fields travelling through the prosthesis. A fixed-field measurement showed a dose reduction of 52% in the shadow of the prosthesis. A Monte Carlo simulation confirmed an increase in dose on the distal surface of the prosthesis of 35%. Of more clinical relevance, however, is the dose distribution due to the overall combined field treatment. Using a power law correction benchmarked against thermoluminescent dosimeters and Gafchromic film, three different beam set-ups for patient treatment were planned and the dose variation analysed. A four-field brick technique gave a dose variation across the target volume of +/- 15% whereas a dual arc technique gave a dose variation of only +/- 5%. A four-field oblique technique gave a dose variation of only +/- 2% across the target volume but the oblique field technique included extra dose to the rectum.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10974722     DOI: 10.1046/j.1440-1673.2000.00816.x

Source DB:  PubMed          Journal:  Australas Radiol        ISSN: 0004-8461


  10 in total

1.  Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2007-12-25

2.  Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

Authors:  Manuel Maerz; Oliver Koelbl; Barbara Dobler
Journal:  Strahlenther Onkol       Date:  2014-10-31       Impact factor: 3.621

3.  Evaluation of the radiotherapy treatment planning in the presence of a magnetic valve tissue expander.

Authors:  Débora M Trombetta; Simone C Cardoso; Victor G L Alves; Alessandro Facure; Delano V S Batista; Ademir X da Silva
Journal:  PLoS One       Date:  2015-02-13       Impact factor: 3.240

4.  An opposed matched field IMRT technique for prostate cancer patients with bilateral prosthetic hips.

Authors:  Shahin Fattahi; Orest Z Ostapiak
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

5.  Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.

Authors:  Nicholas Ade; F C P du Plessis
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

6.  Improvement of dose calculation in radiation therapy due to metal artifact correction using the augmented likelihood image reconstruction.

Authors:  Christian Ziemann; Maik Stille; Florian Cremers; Thorsten M Buzug; Dirk Rades
Journal:  J Appl Clin Med Phys       Date:  2018-04-17       Impact factor: 2.102

7.  Dosimetry Effects Caused by Unilateral and Bilateral Hip Prostheses: A Monte Carlo Case Study in Megavoltage Photon Radiotherapy for Computed Tomography Data without Metal Artifacts.

Authors:  Courage Mahuvava; Frederik Carl Phillipus Du Plessis
Journal:  J Med Phys       Date:  2018 Oct-Dec

8.  Effect of Hip Prosthesis on Photon Beam Characteristics in Radiological Physics.

Authors:  Manindra Bhushan; Deepak Tripathi; Girigesh Yadav; Lalit Kumar; Abhinav Dewan; Gourav Kumar
Journal:  Asian Pac J Cancer Prev       Date:  2020-06-01

9.  A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses.

Authors:  Suresh B Rana; Shyam Pokharel
Journal:  South Asian J Cancer       Date:  2014-01

10.  A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.

Authors:  Mohammad Taghi Bahreyni Toossi; Marziyeh Behmadi; Mahdi Ghorbani; Hamid Gholamhosseinian
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.