Literature DB >> 10969371

Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit.

P V van Heerden1, S Baker, S I Lim, C Weidman, M Bulsara.   

Abstract

The Non-invasive Cardiac Output (NICO) monitor (Novametrix Medical Systems Inc., Wallingford, CT, U.S.A.) utilizes a minimally-invasive partial rebreathing method to determine cardiac output by means of a differential form of the Fick equation. We evaluated the NICO monitor by comparing its output to paired measurements obtained by the standard thermodilution (TD) technique in patients who had recently undergone cardiac surgery. Forty-two paired measurements were carried out in 12 patients. The correlation between the two methods was moderate with a correlation coefficient of 0.691. Repeated measures ANOVA showed that TD measures of cardiac output were significantly higher than those obtained by the NICO monitor (P = 0.0003). Comparison of the two techniques using the method described by Bland and Altman showed decreased correlation at higher values of cardiac output. We conclude that the NICO monitor may well have a place in intensive care monitoring, provided patients are not breathing spontaneously and are able to tolerate a 4 mmHg rise in PaCO2. It is less suitable for use in patients with a high cardiac output state.

Entities:  

Mesh:

Year:  2000        PMID: 10969371     DOI: 10.1177/0310057X0002800412

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  11 in total

Review 1.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

2.  A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation.

Authors:  Monica Rocco; Gustavo Spadetta; Andrea Morelli; Donatella Dell'Utri; Patrizia Porzi; Giorgio Conti; Paolo Pietropaoli
Journal:  Intensive Care Med       Date:  2003-12-03       Impact factor: 17.440

3.  [Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].

Authors:  J Reutershan; T Kapp; K Unertl; R Fretschner
Journal:  Anaesthesist       Date:  2003-09       Impact factor: 1.041

4.  Improved accuracy of cardiac output estimation by the partial CO2 rebreathing method.

Authors:  Yoshifumi Kotake; Takashige Yamada; Hiromasa Nagata; Takeshi Suzuki; Ryohei Serita; Nobuyuki Katori; Junzo Takeda; Hideyuki Shimizu
Journal:  J Clin Monit Comput       Date:  2009-03-20       Impact factor: 2.502

5.  Cardiac output assessed by invasive and minimally invasive techniques.

Authors:  Allison J Lee; Jennifer Hochman Cohn; J Sudharma Ranasinghe
Journal:  Anesthesiol Res Pract       Date:  2011-07-06

6.  Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.

Authors:  Kazuya Tachibana; Hideaki Imanaka; Muneyuki Takeuchi; Tomoyo Nishida; Yuji Takauchi; Masaji Nishimura
Journal:  Crit Care       Date:  2005-09-07       Impact factor: 9.097

Review 7.  Equipment review: the success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation.

Authors:  Scott R Gunn; Mitchell P Fink; Benjamin Wallace
Journal:  Crit Care       Date:  2005-05-27       Impact factor: 9.097

8.  A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis.

Authors:  A Vakily; H Parsaei; M M Movahhedi; M A Sahmeddini
Journal:  J Biomed Phys Eng       Date:  2017-06-01

9.  Technological advancements in the care of the trauma patient.

Authors:  J J Siracuse; N N Saillant; C J Hauser
Journal:  Eur J Trauma Emerg Surg       Date:  2011-11-09       Impact factor: 3.693

Review 10.  Equipment review: new techniques for cardiac output measurement--oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis.

Authors:  Christine Berton; Bernard Cholley
Journal:  Crit Care       Date:  2002-04-25       Impact factor: 9.097

View more