Literature DB >> 10952109

Applying computer-assisted detection schemes to digitized mammograms after JPEG data compression: an assessment.

B Zheng1, J H Sumkin, W F Good, G S Maitz, Y H Chang, D Gur.   

Abstract

RATIONALE AND
OBJECTIVES: The authors' purpose was to assess the effects of Joint Photographic Experts Group (JPEG) image data compression on the performance of computer-assisted detection (CAD) schemes for the detection of masses and microcalcification clusters on digitized mammograms.
MATERIALS AND METHODS: This study included 952 mammograms that were digitized and compressed with a JPEG-compatible image-compression scheme. A CAD scheme, previously developed in the authors' laboratory and optimized for noncompressed images, was applied to reconstructed images after compression at five levels. The performance was compared with that obtained with the original noncompressed digitized images.
RESULTS: For mass detection, there were no significant differences in performance between noncompressed and compressed images for true-positive regions (P = .25) or false-positive regions (P = .40). In all six modes the scheme identified 80% of masses with less than one false-positive region per image. For the detection of microcalcification clusters, there was significant performance degradation (P < .001) at all compression levels. Detection sensitivity was reduced by 4%-10% as compression ratios increased from 17:1 to 62:1. At the same time, the false-positive detection rate was increased by 91%-140%.
CONCLUSION: The JPEG algorithm did not adversely affect the performance of the CAD scheme for detecting masses, but it did significantly affect the detection of microcalcification clusters.

Mesh:

Year:  2000        PMID: 10952109     DOI: 10.1016/s1076-6332(00)80574-7

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  8 in total

1.  Interactive computer-aided diagnosis of breast masses: computerized selection of visually similar image sets from a reference library.

Authors:  Bin Zheng; Claudia Mello-Thoms; Xiao-Hui Wang; Gordon S Abrams; Jules H Sumkin; Denise M Chough; Marie A Ganott; Amy Lu; David Gur
Journal:  Acad Radiol       Date:  2007-08       Impact factor: 3.173

2.  Improving performance of content-based image retrieval schemes in searching for similar breast mass regions: an assessment.

Authors:  Xiao-Hui Wang; Sang Cheol Park; Bin Zheng
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

3.  A new and fast image feature selection method for developing an optimal mammographic mass detection scheme.

Authors:  Maxine Tan; Jiantao Pu; Bin Zheng
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

4.  Full-field digital mammography image data storage reduction using a crop tool.

Authors:  Bong Joo Kang; Sung Hun Kim; Yeong Yi An; Byung Gil Choi
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-10       Impact factor: 2.924

5.  Computer-aided detection of breast masses depicted on full-field digital mammograms: a performance assessment.

Authors:  B Zheng; J H Sumkin; M L Zuley; D Lederman; X Wang; D Gur
Journal:  Br J Radiol       Date:  2011-02-22       Impact factor: 3.039

6.  Computer-Aided Diagnosis in Mammography Using Content-based Image Retrieval Approaches: Current Status and Future Perspectives.

Authors:  Bin Zheng
Journal:  Algorithms       Date:  2009-06-01

7.  Quantitative visually lossless compression ratio determination of JPEG2000 in digitized mammograms.

Authors:  Verislav T Georgiev; Anna N Karahaliou; Spyros G Skiadopoulos; Nikos S Arikidis; Alexandra D Kazantzi; George S Panayiotakis; Lena I Costaridou
Journal:  J Digit Imaging       Date:  2013-06       Impact factor: 4.056

8.  Improving performance of computer-aided detection scheme by combining results from two machine learning classifiers.

Authors:  Sang Cheol Park; Jiantao Pu; Bin Zheng
Journal:  Acad Radiol       Date:  2009-03       Impact factor: 3.173

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.