Artificial anal sphincter: prospective clinical and manometric evaluation.

P A Lehur1, J V Roig, M Duinslaeger.   

Abstract

INTRODUCTION: Artificial anal sphincter has been proposed in severe anal incontinence when local treatment is unsuitable or has failed. The outcome after implantation of this newly developed device has not yet been determined.
METHODS: Twenty-four consecutive patients (7 men; median age, 44; standard deviation, 18; range, 14-80 years) implanted since May 1996 for a minimum of six months at three centers were prospectively evaluated. Continence (scoring system, 0 (normal) to 120 (complete incontinence)), rectal emptying, and general satisfaction were assessed clinically and at anal manometry preoperatively and postoperatively at a six-month interval. The causes of incontinence included anal trauma (9 cases), neuropathy (6 cases), neurologic disorders (4 cases), congenital malformations (3 cases), and prolapse (2 cases). Median duration of incontinence was 7.5 (standard deviation, 8) years. Stomas pre-existed in two cases and was created at implantation in one.
RESULTS: Median follow-up was 20 (standard deviation, 8; range, 10-35) months. Seven patients had their devices explanted, and reimplantation was successfully performed in three of these cases. At the end of follow-up, 20 (83 percent) patients had an implanted activated device. Fecal incontinence score dropped significantly from a median 106 (standard deviation, 13) preoperatively to 19 (standard deviation, 32), 25 (standard deviation, 29), and 25 (standard deviation, 25) at six months, one year, and the end of follow-up, respectively (P<0.0001). Minor and major emptying difficulties occurred in seven and two patients, respectively. A high degree of satisfaction was achieved at the end of follow-up in 18 (75 percent) of the total series. Median anal pressures at rest on manometry increased significantly from 28 (standard deviation, 17; range, 5-76) mm Hg preoperatively to 60 (standard deviation, 17; range, 38-96) mmHg with a closed cuff at the end of follow-up. These pressures dropped to 30 (standard deviation, 16; range, 9-65) mm Hg with an open cuff, and reocclusion time lasted a median of 4.6 minutes (standard deviation, 3 minutes; range, 38 seconds to 10 minutes).
CONCLUSION: Artificial anal sphincter provided prolonged and reasonably good functional results in severe incontinence, reproducing an efficient sphincteric mechanism and allowing satisfactory anal occlusion and rectal emptying in approximately 75 percent of cases in this study. The definitive explantation rate was kept low by careful patient selection and appropriate surgical and perioperative management.

Entities:  

Mesh:

Year:  2000        PMID: 10950008     DOI: 10.1007/bf02236557

Source DB:  PubMed          Journal:  Dis Colon Rectum        ISSN: 0012-3706            Impact factor:   4.585


  17 in total

Review 1.  Novel surgical approaches to fecal incontinence: neurostimulation and artificial anal sphincter.

Authors:  Xiaotuan Zhao; Pankaj J Pasricha
Journal:  Curr Gastroenterol Rep       Date:  2003-10

2.  Electromagnetic effects on the biological tissue surrounding a transcutaneous transformer for an artificial anal sphincter system.

Authors:  Peng Zan; Bang-hua Yang; Yong Shao; Guo-zheng Yan; Hua Liu
Journal:  J Zhejiang Univ Sci B       Date:  2010-12       Impact factor: 3.066

Review 3.  Challenges faced in the clinical application of artificial anal sphincters.

Authors:  Ming-hui Wang; Ying Zhou; Shuang Zhao; Yun Luo
Journal:  J Zhejiang Univ Sci B       Date:  2015-09       Impact factor: 3.066

Review 4.  Investigation and treatment of faecal incontinence.

Authors:  S Maslekar; A Gardiner; C Maklin; G S Duthie
Journal:  Postgrad Med J       Date:  2006-06       Impact factor: 2.401

Review 5.  [Dynamic graciloplasty vs artificial bowel sphincter in the management of severe fecal incontinence].

Authors:  O Ruthmann; A Fischer; U T Hopt; H J Schrag
Journal:  Chirurg       Date:  2006-10       Impact factor: 0.955

Review 6.  Neosphincter surgery for fecal incontinence: a critical and unbiased review of the relevant literature.

Authors:  Orlin Belyaev; Christophe Müller; Waldemar Uhl
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

7.  Fecal incontinence.

Authors:  Tracy Hull
Journal:  Clin Colon Rectal Surg       Date:  2007-05

8.  The possibility of muscle tissue reconstruction using shape memory alloys.

Authors:  Yun Luo; Masaru Higa; Shintaro Amae; Tomoyuki Yambe; Takeshi Okuyama; Toshiyuki Takagi; Hidetoshi Matsuki
Journal:  Organogenesis       Date:  2005-01       Impact factor: 2.500

9.  The current status of the Acticon Neosphincter.

Authors:  Sharon G Gregorcyk
Journal:  Clin Colon Rectal Surg       Date:  2005-02

10.  Short-term outcome of percutaneous posterior tibial nerve stimulation (PTNS) for the treatment of faecal incontinence.

Authors:  E Peña Ros; P A Parra Baños; J A Benavides Buleje; J M Muñoz Camarena; C Escamilla Segade; M F Candel Arenas; F M Gonzalez Valverde; A Albarracín Marín-Blázquez
Journal:  Tech Coloproctol       Date:  2016-01       Impact factor: 3.781

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.