Literature DB >> 10943937

Mean and variance of single photon counting with deadtime.

D F Yu1, J A Fessler.   

Abstract

The statistics of photon counting by systems affected by deadtime are potentially important for statistical image reconstruction methods. We present a new way of analysing the moments of the counting process for a counter system affected by various models of deadtime related to PET and SPECT imaging. We derive simple and exact expressions for the first and second moments of the number of recorded events under various models. From our mean expression for a SPECT deadtime model, we derive a simple estimator for the actual intensity of the underlying Poisson process; simulations show that our estimator is unbiased even for extremely high count rates. From this analysis, we study the suitability of the Poisson statistical model assumed in most statistical image reconstruction algorithms. For systems containing 'modules' with several detector elements, where each element can cause deadtime losses for the entire module, such as block PET detectors or Anger cameras, the Poisson statistical model appears to be adequate even in the presence of deadtime losses.

Mesh:

Year:  2000        PMID: 10943937     DOI: 10.1088/0031-9155/45/7/324

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Sizing-up finite fluorescent particles with nanometer-scale precision by convolution and correlation image analysis.

Authors:  Arne Gennerich; Detlev Schild
Journal:  Eur Biophys J       Date:  2004-12-18       Impact factor: 1.733

Review 2.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Signal to noise ratio of energy selective x-ray photon counting systems with pileup.

Authors:  Robert E Alvarez
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

4.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07

5.  The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

Review 6.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

7.  First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements.

Authors:  Abdul K Rumaiz; D Peter Siddons; Grzegorz Deptuch; Piotr Maj; Anthony J Kuczewski; Gabriella A Carini; Suresh Narayanan; Eric M Dufresne; Alec Sandy; Robert Bradford; Andrei Fluerasu; Mark Sutton
Journal:  J Synchrotron Radiat       Date:  2016-02-10       Impact factor: 2.616

8.  Cross-calibration of a combined electrostatic and time-of-flight analyzer for energy- and charge-state-resolved spectrometry of tin laser-produced plasma.

Authors:  L Poirier; A Bayerle; A Lassise; F Torretti; R Schupp; L Behnke; Y Mostafa; W Ubachs; O O Versolato; R Hoekstra
Journal:  Appl Phys B       Date:  2022-02-05       Impact factor: 2.070

9.  High-rate dead-time corrections in a general purpose digital pulse processing system.

Authors:  Leonardo Abbene; Gaetano Gerardi
Journal:  J Synchrotron Radiat       Date:  2015-08-07       Impact factor: 2.616

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.