Effects of hip joint centre mislocation on gait analysis results.

R Stagni1, A Leardini, A Cappozzo, M Grazia Benedetti, A Cappello.   

Abstract

Methods to determine the hip joint centre (HJC) location are necessary in gait analysis. It has been demonstrated that the methods proposed in the literature involve large mislocation errors. The choice should be made according to the extent by which HJC location errors distort the estimates of angles and resultant moments at the hip and knee joints. This study aimed at quantifying how mislocation errors propagate to these gait analysis results. Angles and moments at the hip and knee joint were calculated for five able-bodied subjects during level walking. The nominal position of the HJC was determined as the position of the pivot point of a 3D movement of the thigh relative to the pelvis. Angles and moments were then re-calculated after having added to HJC co-ordinates errors in the range of +/-30 mm. Angles and moments at both hip and knee joints were affected by HJC mislocation. The hip moments showed the largest propagation error: a 30 mm HJC anterior mislocation resulted in a propagated error into flexion/extension component of about -22%. The hip abduction/adduction moment was found the second largest affected quantity: a 30 mm lateral HJC mislocation produced a propagated error of about -15%. Finally, a 30 mm posterior HJC mislocation produced a delay of the flexion-to-extension timing in the order of 25% of the stride duration. HJC estimation methods with minimum antero-posterior error should therefore be preferred.

Mesh:

Year:  2000        PMID: 10940407     DOI: 10.1016/s0021-9290(00)00093-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  19 in total

1.  Kinematic study of a reconstructed hip in paediatric oncology.

Authors:  F Taddei; A Stagni; M Cappello; R Manfrini; U Albisinni; M Viceconti
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

2.  3D inverse dynamics in non-orthonormal segment coordinate system.

Authors:  R Dumas; L Chèze
Journal:  Med Biol Eng Comput       Date:  2007-01-25       Impact factor: 2.602

3.  Are patient-specific joint and inertial parameters necessary for accurate inverse dynamics analyses of gait?

Authors:  Jeffrey A Reinbolt; Raphael T Haftka; Terese L Chmielewski; Benjamin J Fregly
Journal:  IEEE Trans Biomed Eng       Date:  2007-05       Impact factor: 4.538

4.  Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre.

Authors:  Amity Cree Campbell; J A Alderson; D G Lloyd; B C Elliott
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

5.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

6.  A probabilistic approach to quantify the impact of uncertainty propagation in musculoskeletal simulations.

Authors:  Casey A Myers; Peter J Laz; Kevin B Shelburne; Bradley S Davidson
Journal:  Ann Biomed Eng       Date:  2014-11-18       Impact factor: 3.934

Review 7.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

8.  Design of Optimal Treatments for Neuromusculoskeletal Disorders using Patient-Specific Multibody Dynamic Models.

Authors:  Benjamin J Fregly
Journal:  Int J Comput Vis Biomech       Date:  2009-07-01

9.  In-vivo quantification of dynamic hip joint center errors and soft tissue artifact.

Authors:  Niccolo M Fiorentino; Penny R Atkins; Michael J Kutschke; K Bo Foreman; Andrew E Anderson
Journal:  Gait Posture       Date:  2016-09-11       Impact factor: 2.840

10.  Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

Authors:  Niccolo M Fiorentino; Michael J Kutschke; Penny R Atkins; K Bo Foreman; Ashley L Kapron; Andrew E Anderson
Journal:  Ann Biomed Eng       Date:  2015-12-08       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.