Literature DB >> 10931580

Safety of MR scanning in patients with nonferromagnetic aneurysm clips.

G L Pride1, J Kowal, D B Mendelsohn, D P Chason, J L Fleckenstein.   

Abstract

The purpose of this study was to report our surveillance of patients with nonferromagnetic aneurysm clips (NFAC) who have undergone magnetic resonance imaging (MRI). Forty-six patients with NFAC underwent MRI over a 7-year period. Medical records were studied for evidence of subjective or objective clinical findings as a result of the MRI scan. In two patients with subjective complaints, computed tomograms (CT) were reviewed and patient interviews conducted. No significant neurologic signs or longterm symptoms were experienced. Two patients did not complete their MRI scans due to transient unilateral head pain in one and head "pressure" in another. CT scans in these patients demonstrated no evidence for hemorrhage or visible change in clip position. We documented no objective adverse outcome of patients undergoing MRI with NFAC, confirming that MRI can be performed safely in patients with nonferromagnetic aneurysm clips. The cause of subjective complaints in two of our patients is unknown.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10931580     DOI: 10.1002/1522-2586(200007)12:1<198::aid-jmri22>3.0.co;2-t

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients.

Authors:  Faraz Khursheed; Fiona Rohlffs; Shuichi Suzuki; Dong H Kim; Timothy M Ellmore
Journal:  BMC Med Imaging       Date:  2011-10-04       Impact factor: 1.930

2.  Aneurysm clips: evaluation of magnetic field interactions and translational attraction by use of "long-bore" and "short-bore" 3.0-T MR imaging systems.

Authors:  Frank G Shellock; Jean A Tkach; Paul M Ruggieri; Thomas J Masaryk; Peter A Rasmussen
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

3.  In vitro evaluation of MR imaging issues at 3T for aneurysm clips made from MP35N: Findings and information applied to 155 additional aneurysm clips.

Authors:  F G Shellock; S Valencerina
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-24       Impact factor: 3.825

Review 4.  Patient safety issues in magnetic resonance imaging: state of the art.

Authors:  A Stecco; A Saponaro; A Carriero
Journal:  Radiol Med       Date:  2007-06-11       Impact factor: 6.313

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.