Literature DB >> 10931570

Aneurysm clips: evaluation of magnetic field interactions with an 8.0 T MR system.

A Kangarlu1, F G Shellock.   

Abstract

This study was conducted to evaluate magnetic field interactions for aneurysm clips exposed to an 8.0 T magnetic resonance (MR) system. Twenty-six different aneurysm clips were tested for magnetic field translational attraction (deflection angle test) and torque (qualitative assessment method) using previously described techniques. Six of the specific aneurysm clips (i.e. type, model, blade length) made from stainless steel alloy (Perneczky) and Phynox (Yasargil, models FE 748 and FE 750) displayed deflection angles above 45 degrees and torque measurements of +4, indicating that these aneurysm clips maybe unsafe for patients or individuals in an 8.0 T MR environment. The specific aneurysm clips (i.e. type, model, blade length) made from commercially pure titanium (Spetzler), Elgiloy (Sugita), titanium alloy (Yasargil, model FE 750T), and MP35N (Sundt) displayed deflection angles less than 45 degrees and torque that ranged from + 1 to +4. Accordingly, these aneurysm clips are likely to be safe for patients or individuals exposed to an 8.0 T MR system. Depending on the actual dimensions and mass, an aneurysm clip made from Elgiloy may or may not be acceptable for a patient or individual in the 8.0 T MR environment.

Entities:  

Mesh:

Year:  2000        PMID: 10931570     DOI: 10.1002/1522-2586(200007)12:1<107::aid-jmri12>3.0.co;2-5

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems.

Authors:  J Kemper; A N Priest; D Schulze; B Kahl-Nieke; G Adam; A Klocke
Journal:  Eur Radiol       Date:  2006-06-29       Impact factor: 5.315

2.  Radiofrequency-induced heating near fixed orthodontic appliances in high field MRI systems at 3.0 Tesla.

Authors:  Marc Regier; Jörn Kemper; Michael G Kaul; Markus Feddersen; Gerhard Adam; Bärbel Kahl-Nieke; Arndt Klocke
Journal:  J Orofac Orthop       Date:  2009-12-04       Impact factor: 1.938

3.  Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients.

Authors:  Faraz Khursheed; Fiona Rohlffs; Shuichi Suzuki; Dong H Kim; Timothy M Ellmore
Journal:  BMC Med Imaging       Date:  2011-10-04       Impact factor: 1.930

4.  Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI.

Authors:  S Tsutsui; T Matsuda; K Takeda; M Sasaki; Y Kubo; K Setta; S Fujiwara; K Chida; K Ogasawara
Journal:  AJNR Am J Neuroradiol       Date:  2022-06-23       Impact factor: 4.966

5.  Aneurysm clips: evaluation of magnetic field interactions and translational attraction by use of "long-bore" and "short-bore" 3.0-T MR imaging systems.

Authors:  Frank G Shellock; Jean A Tkach; Paul M Ruggieri; Thomas J Masaryk; Peter A Rasmussen
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

6.  Mechanisms and prevention of thermal injury from gamma radiosurgery headframes during 3T MR imaging.

Authors:  Marcus C Bennett; David B Wiant; Jacob A Gersh; Wendy Dolesh; X Ding; Ryan C M Best; J D Bourland
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

7.  A Novel Magnetic Resonance Imaging-Compatible Titanium Alloy Wire-Reinforced Endotracheal Tube.

Authors:  Bikei Ryu; Yoshikazu Okada; Nobuko Fujita; Yasuko Nagasaka
Journal:  Materials (Basel)       Date:  2022-08-16       Impact factor: 3.748

  7 in total