Literature DB >> 19045509

A phantom tissue system for the calibration of perfusion measurements.

Ashvinikumar V Mudaliar1, Brent E Ellis, Patricia L Ricketts, Otto I Lanz, Elaine P Scott, Thomas E Diller.   

Abstract

A convenient method for testing and calibrating surface perfusion sensors has been developed. A phantom tissue model is used to simulate the nondirectional blood flow of tissue perfusion. A computational fluid dynamics (CFD) model was constructed in Fluent(R) to design the phantom tissue and validate the experimental results. The phantom perfusion system was used with a perfusion sensor based on clearance of thermal energy. A heat flux gage measures the heat flux response of tissue when a thermal event (convective cooling) is applied. The blood perfusion and contact resistance are estimated by a parameter estimation code. From the experimental and analytical results, it was concluded that the probe displayed good measurement repeatability and sensitivity. The experimental perfusion measurements in the tissue were in good agreement with those of the CFD models and demonstrated the value of the phantom tissue system.

Entities:  

Mesh:

Year:  2008        PMID: 19045509      PMCID: PMC2596616          DOI: 10.1115/1.2948417

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  17 in total

1.  Serial measurements increase the accuracy of laser Doppler assessment of burn wounds.

Authors:  W J Mileski; L Atiles; G Purdue; R Kagan; J R Saffle; D N Herndon; D Heimbach; A Luterman; R Yurt; C Goodwin; J L Hunt
Journal:  J Burn Care Rehabil       Date:  2003 Jul-Aug

2.  Development of a new method for monitoring blood purification: the blood flow analysis of the head and foot by laser Doppler blood flowmeter during hemodialysis.

Authors:  Jun Niwayama; Tsutomu Sanaka
Journal:  Hemodial Int       Date:  2005-01       Impact factor: 1.812

3.  Analysis of tissue and arterial blood temperatures in the resting human forearm.

Authors:  H H PENNES
Journal:  J Appl Physiol       Date:  1948-08       Impact factor: 3.531

4.  Monitoring of the intestinal mucosal perfusion using laser Doppler flowmetry after multivisceral transplantation.

Authors:  M Oltean; A Aneman; G Dindelegan; J Mölne; M Olausson; G Herlenius
Journal:  Transplant Proc       Date:  2005-10       Impact factor: 1.066

Review 5.  Noninvasive blood flow measurement.

Authors:  J P Woodcock
Journal:  Crit Rev Biomed Eng       Date:  1985

6.  Thermal diffusion probe analysis of perfusion changes in vascular occlusions of rabbit pedicle flaps.

Authors:  Monica B Khot; Peter K M Maitz; Benjamin R Phillips; H Friederick Bowman; Julian J Pribaz; Dennis P Orgill
Journal:  Plast Reconstr Surg       Date:  2005-04       Impact factor: 4.730

7.  The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue.

Authors:  J W Valvano; J T Allen; H F Bowman
Journal:  J Biomech Eng       Date:  1984-08       Impact factor: 2.097

8.  Measurements of tissue blood flow by the hydrogen clearance technique (HCT): a comparative study including laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO).

Authors:  H G Machens; N Pallua; P Mailaender; J Pasel; K H Frank; R Reimer; A Berger
Journal:  Microsurgery       Date:  1995       Impact factor: 2.425

9.  Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging.

Authors:  Xavier Montet; Marko K Ivancevic; Jacques Belenger; Manuel Jorge-Costa; Sybille Pochon; Antoinette Pechère; François Terrier; Jean-Paul Vallée
Journal:  Invest Radiol       Date:  2003-09       Impact factor: 6.016

10.  Evaluation of laser Doppler flowmetry for measurement of capillary blood flow in the stomach wall of dogs during gastric dilatation-volvulus.

Authors:  Eric Monnet; Davyd Pelsue; Catriona MacPhail
Journal:  Vet Surg       Date:  2006-02       Impact factor: 1.495

View more
  2 in total

1.  Non-Invasive Blood Perfusion Measurements Using a Combined Temperature and Heat Flux Surface Probe.

Authors:  Patricia L Ricketts; Ashvinikumar V Mudaliar; Brent E Ellis; Clay A Pullins; Leah A Meyers; Otto I Lanz; Elaine P Scott; Thomas E Diller
Journal:  Int J Heat Mass Transf       Date:  2008-11-01       Impact factor: 5.584

2.  Noninvasive blood perfusion measurements of an isolated rat liver and an anesthetized rat kidney.

Authors:  Ashvinikumar V Mudaliar; Brent E Ellis; Patricia L Ricketts; Otto I Lanz; Charles Y Lee; Thomas E Diller; Elaine P Scott
Journal:  J Biomech Eng       Date:  2008-12       Impact factor: 2.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.