Literature DB >> 10893133

Carotid stenting with cerebral protection: first clinical experience using the PercuSurge GuardWire system.

M Henry1, M Amor, I Henry, C Klonaris, Z Chati, I Masson, S Kownator, F Luizy, M Hugel.   

Abstract

PURPOSE: To study the feasibility and safety of carotid angioplasty and stenting using a new cerebral protection device that temporarily occludes the distal internal carotid artery (ICA).
METHODS: Forty-eight high-risk patients (39 men, mean age 69.1 +/- 8 years, range 54 to 86) with 53 ICA stenoses underwent percutaneous angioplasty and stenting via the femoral approach under cerebral protection afforded by a 0.014-inch GuardWire balloon occlusion device. Mean stenosis was 82.1% +/- 9.65% (range 70 to 96) and mean lesion length was 16.0 +/- 7.5 mm (range 6 to 50). Thirty-three (62%) lesions were calcified, and 38 (72%) were ulcerated. Thirty-two (60%) of the lesions were asymptomatic. With the occlusion balloon inflated in the distal ICA, the lesion was dilated and stented. The area was cleaned by aspiration and flushed via an aspiration catheter advanced over the wire. Blood samples were collected from the external carotid artery (ECA) and analyzed to measure the size and number of particles collected. Computed tomography and neurological examinations were performed the day after the procedure.
RESULTS: Immediate technical success was achieved in all patients with the implantation of 38 Palmaz stents, 8 Expander stents, and 11 Wallstents. Carotid occlusion was well tolerated in all patients but 1 who had multiple, severe carotid lesions and poor collateralization. Mean cerebral flow occlusion time was 346 +/- 153 seconds during predilation and 303 +/- 143 seconds during stent placement. Total mean flow occlusion time was 542 +/- 243 seconds. One immediate neurological complication (transient amaurosis) occurred in a patient who had an anastomosis between the external carotid (EC) and ICA territories. Debris was removed in all patients with a mean 0.8-mm diameter catheter.
CONCLUSION: Cerebral protection with the GuardWire device is easy, safe, and effective in protecting the brain from cerebral embolism. Larger studies are warranted.

Entities:  

Mesh:

Year:  1999        PMID: 10893133     DOI: 10.1177/152660289900600405

Source DB:  PubMed          Journal:  J Endovasc Surg        ISSN: 1074-6218


  19 in total

1.  Carotid artery stenting: technical considerations.

Authors:  J J Vitek; G S Roubin; N Al-Mubarek; G New; S S Iyer
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

2.  Quality improvement guidelines for the performance of cervical carotid angioplasty and stent placement.

Authors:  John D Barr; John J Connors; David Sacks; Joan C Wojak; Gary J Becker; John F Cardella; Bohdan Chopko; Jacques E Dion; Allan J Fox; Randall T Higashida; Robert W Hurst; Curtis A Lewis; Terence A S Matalon; Gary M Nesbit; J Arliss Pollock; Eric J Russell; David J Seidenwurm; Robert C Wallace
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

3.  Embolic protection devices.

Authors:  G Sangiorgi; A Colombo
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

4.  Abrupt Flow Arrest in the Internal Carotid Artery during Carotid Artery Stenting Using the Parodi Anti-Emboli System.

Authors:  H Oishi; N Horinaka; H Arai
Journal:  Interv Neuroradiol       Date:  2006-02-10       Impact factor: 1.610

5.  Treatment of cervical carotid artery stenosis.

Authors:  S Yoshimura
Journal:  Interv Neuroradiol       Date:  2008-05-15       Impact factor: 1.610

6.  Stent-supported angioplasty versus endarterectomy for carotid artery stenosis: evidence from current randomized trials.

Authors:  R Zahn; M Hochadel; A Grau; J Senges
Journal:  Z Kardiol       Date:  2005-12

7.  Reversal of flow during carotid artery stenting: use of the Parodi antiembolism system.

Authors:  Iris Q Grunwald; Panagiotis Papanagiotou; Tobias Struffert; Maria Politi; Christoph Krick; Bernd F M Romaike; Frank Ahlhelm; Wolfgang Reith
Journal:  Neuroradiology       Date:  2007-01-05       Impact factor: 2.804

8.  Carotid artery stent placement with distal balloon protection: technical considerations.

Authors:  Jiri J Vitek; Nadim Al-Mubarak; Sriram S Iyer; Gary S Roubin
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

9.  Carotid intervention 3: the evidence for cerebral protection.

Authors:  Fabrizio Fanelli; Mario Bezzi; Emanuele Boatta; Roberto Passariello
Journal:  Semin Intervent Radiol       Date:  2007-06       Impact factor: 1.513

10.  Carotid artery stenting in clinical practice results from the Carotid Artery Stenting (CAS)-registry of the Arbeitsgemeinschaft Leitende Kardiologische Krankenhausarzte (ALKK).

Authors:  R Zahn; E Roth; T Ischinger; B Mark; M Hochadel; U Zeymer; K Haerten; K E Hauptmann; E-R von Leitner; A Schramm; W Kasper; J Senges
Journal:  Z Kardiol       Date:  2005-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.