Literature DB >> 10884197

Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips.

J Thanner1, J Kärrholm, P Herberts, H Malchau.   

Abstract

Sixty-two patients (64 hips) were provided with porous press-fit cups (Trilogy), plasma-sprayed with a coating consisting of 70% hydroxyapatite and 30% tricalcium phosphate. The patients were randomized to a cup with cluster holes for adjunctive screw fixation (n = 30) or to a cup without holes (n = 34). Radiostereometry was used to study migration and wear. Up to 2 years median translations and rotations <0.2 mm and <0.2 degrees were recorded in the 2 groups, without any difference. The median annual proximal wear (0.11 and 0.12 mm) was within the expected range despite the use of a ceramic coating, and it did not differ between the 2 designs. Radiolucent lines were frequently seen postoperatively but diminished during the follow-up without any sign of migration into the gaps. At 2 years, the median Harris scores were 99 points (range, 51-100 points) in the group with and 98 points (range, 69-100 points) in the group without screws. The results indicate that early fixation can be achieved for ceramic-coated press-fit cups without using additional screw fixation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10884197     DOI: 10.1054/arth.2000.2963

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  19 in total

1.  The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometry.

Authors:  Olof Wolf; Per Mattsson; Jan Milbrink; Sune Larsson; Hans Mallmin
Journal:  Int Orthop       Date:  2011-12-07       Impact factor: 3.075

2.  The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

Authors:  Kjeld Søballe; Olivier R G Mouzin; Louis A Kidder; Søren Overgaard; Joan E Bechtold
Journal:  Acta Orthop Scand       Date:  2003-06

3.  A long-term follow-up study of the cementless THA with anatomic stem/HGPII cup with 22-mm head.

Authors:  Yutaka Nakoshi; Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Int Orthop       Date:  2008-01-09       Impact factor: 3.075

4.  Press-fit cementless acetabular fixation with and without screws.

Authors:  Sheng-Hui Ni; Lei Guo; Tian-Long Jiang; Jie Zhao; Yan-Gang Zhao
Journal:  Int Orthop       Date:  2013-08-28       Impact factor: 3.075

5.  Bone remodelling around HA-coated acetabular cups : a DEXA study with a 3-year follow-up in a randomised trial.

Authors:  M B Laursen; P T Nielsen; K Søballe
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

6.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

7.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

8.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

9.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

10.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.